Alignment of rotational axes in asynchronous late type binaries

نویسنده

  • R. Glȩbocki
چکیده

41 RS CVn and BY Dra type binaries with reliable orbital and physical parameters have been found to rotate asynchronously with the orbital revolution. For this sample inclinations of the rotational axes, ir, of the primaries and the orbital inclinations, io, are independently determined to test the alignment between the equatorial and the orbital planes. The observed difference ∆i = |io − ir| measures a deviation from coplanarity of these planes. It turns out that most asynchronous systems prove to be misaligned, especially when the influence of the position angle is taken into account. Thus, the generally accepted assumption that rotational axes are perpendicular to orbital planes is not valid for asynchronous RS CVn and BY Dra type binaries. The influence of the position angle of the observer on the derived values of ∆i can be studied only by statistical methods. The distribution of the observed ∆i is compared wih the expected values of∆i for two cases: a) the rotational axes are randomly inclined to the orbital planes, and b) the rotational axes are perpendicular to the orbital planes. The best fit to our observed sample of asynchronous binaries is obtained for the case a), while for the synchronous RS CVn and BY Dra type binaries the rotational axes are perpendicular to their orbital planes.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Banana Project. Iv. Two Aligned Stellar Rotation Axes in the Young Eccentric Binary System Epcrucis: Primordial Orientation and Tidal Alignment

With observations of the EPCru system, we continue our series of measurements of spin-orbit angles in eclipsing binary star systems, the BANANA project (Binaries Are Not Always Neatly Aligned). We find a close alignment between the sky projections of the rotational and orbital angular momentum vectors for both stars (βp = −1.8± 1.6◦ and |βs| < 17◦). We also derive precise absolute dimensions an...

متن کامل

Evaluation of Distal Femoral Rotational Alignment with Spiral CT Scan before Total Knee Arthroplasty (A Study in Iranian Population)

    Background: Evaluating the landmarks for rotation of the distal femur is a challenge for orthopedic surgeons. Although the posterior femoral condyle axis is a good landmark for surgeons, the surgical transepicondylar axis may be a better option with the help of preoperative CT scanning. The purpose of this study was to ascertain relationships among the axes’ guiding distal femur rotational ...

متن کامل

THE BANANA PROJECT. IV. TWO ALIGNED STELLAR ROTATION AXES IN THE YOUNG ECCENTRIC BINARY SYSTEM EP CRUCIS: PRIMORDIAL ORIENTATION AND Citation

With observations of the EP Cru system, we continue our series of measurements of spin-orbit angles in eclipsing binary star systems, the BANANA project (Binaries Are Not Always Neatly Aligned). We find a close alignment between the sky projections of the rotational and orbital angular momentum vectors for both stars (βp = −1.8± 1.6◦ and |βs| < 17◦). We also derive precise absolute dimensions a...

متن کامل

Rotational velocities of A - type stars ⋆ III . Velocity distributions

Aims. In this work, a sample of v sin i of B9 to F2-type main sequence single stars has been built from highly homogeneous v sin i parameters determined for a large sample cleansed from objects presenting the Am and Ap phenomenon as well as from all known binaries. The aim is to study the distributions of rotational velocities in the mass range of A-type stars for normal single objects. Methods...

متن کامل

The variability of femoral rotational alignment in total knee arthroplasty.

BACKGROUND Several reference axes are used to establish femoral rotational alignment during total knee arthroplasty, but debate continues with regard to which axis is most accurately and easily identified during surgery. Computer-assisted navigation systems have been developed in an attempt to more accurately and consistently align implants during total knee arthroplasty, but it is unknown if n...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1997