The effect of optical defocus on the test-retest variability of visual acuity measurements.

نویسندگان

  • Daniel A Rosser
  • Ian E Murdoch
  • Simon N Cousens
چکیده

PURPOSE To determine the effect of optical defocus on the test-retest variability (TRV) of visual acuity measurements in normal subjects. METHODS Normal subjects underwent repeated visual acuity measurement with optical defocus of 0, 0.50, and 1.00 D. All measurements were taken using the Early Treatment Diabetic Retinopathy Study (ETDRS) version of the Bailey-Lovie logMAR chart. TRV was quantified in terms of its 95% range, both empirically and using the approach of Bland and Altman. RESULTS According to the Bland and Altman approach, the estimated 95% TRV ranges were +/-0.11 logarithm of the minimum angle of resolution (logMAR) for 0-D defocus, +/-0.18 logMAR for 0.50-D defocus, and +/-0.25 logMAR for 1.00-D defocus. CONCLUSIONS Optical defocus has a considerable effect on the TRV of visual acuity measurements. These findings have important implications for both clinical practice and clinical research. Uncorrected refractive errors as small as 0.50 D may compromise the detection of visual change in individuals, and contribute to unnecessarily large sample sizes in clinical trials in which visual acuity is used as a primary outcome measure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optical defocus: differential effects on size and contrast letter recognition thresholds.

PURPOSE To determine if optical defocus produces a greater reduction in visual acuity or small-letter contrast sensitivity. METHODS Letter charts were used to measure visual acuity and small-letter contrast sensitivity (20/25 Snellen equivalent) as a function of optical defocus. Letter size (acuity) and contrast (contrast sensitivity) were varied in equal logarithmic steps to make the task th...

متن کامل

Effect of scoring and termination rules on test-retest variability of a novel high-pass letter acuity chart.

PURPOSE Test-retest variability (TRV) limits our ability to detect clinically significant changes in visual acuity (VA). We wanted to compare the effect of scoring and termination rules on TRV for logMAR charts, employing either conventional or pseudo high-pass (Vanishing Optotype) letters. METHODS VA measurements and TRV were compared in 50 uncorrected normal observers (17 male, mean age 42....

متن کامل

A Quantitative Investigation on the Effect of Edge Enhancement for Improving Visual Acuity at Different Levels of Contrast

Background: The major limitation in human vision is refractive error. Auxiliary equipment and methods for these people are not always available. In addition, limited range of accommodation in adult people when switching from a far point to a near point is not simply possible. In this paper, we are looking for solutions to use the facilities of digital image processing and displaying to improve ...

متن کامل

Visual Psychophysics and Physiological Optics Effect of Scoring and Termination Rules on Test–Retest Variability of a Novel High-Pass Letter Acuity Chart

Citation: Shah N, Dakin SC, Whitaker HL, Anderson RS. Effect of scoring and termination rules on test–retest variability of a novel high-pass letter acuity chart. Invest Ophthalmol Vis Sci. 2014;55:1386–1392. DOI: 10.1167/iovs.13-13340 PURPOSE. Test–retest variability (TRV) limits our ability to detect clinically significant changes in visual acuity (VA). We wanted to compare the effect of scor...

متن کامل

Effect of Myopic Defocus on Visual Acuity after Phakic Intraocular Lens Implantation and Wavefront-guided Laser in Situ Keratomileusis

This study aimed to investigate the effect of myopic defocus on visual acuity after phakic intraocular lens (IOL) implantation and wavefront-guided laser in situ keratomileusis (wfg-LASIK). Our prospective study comprised thirty eyes undergoing posterior chamber phakic IOL implantation and 30 eyes undergoing wfg-LASIK. We randomly measured visual acuity under myopic defocus after cycloplegic an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 45 4  شماره 

صفحات  -

تاریخ انتشار 2004