Accelerated MR parameter mapping with low-rank and sparsity constraints.
نویسندگان
چکیده
PURPOSE To enable accurate magnetic resonance (MR) parameter mapping with accelerated data acquisition, utilizing recent advances in constrained imaging with sparse sampling. THEORY AND METHODS A new constrained reconstruction method based on low-rank and sparsity constraints is proposed to accelerate MR parameter mapping. More specifically, the proposed method simultaneously imposes low-rank and joint sparse structures on contrast-weighted image sequences within a unified mathematical formulation. With a pre-estimated subspace, this formulation results in a convex optimization problem, which is solved using an efficient numerical algorithm based on the alternating direction method of multipliers. RESULTS To evaluate the performance of the proposed method, two application examples were considered: (i) T2 mapping of the human brain and (ii) T1 mapping of the rat brain. For each application, the proposed method was evaluated at both moderate and high acceleration levels. Additionally, the proposed method was compared with two state-of-the-art methods that only use a single low-rank or joint sparsity constraint. The results demonstrate that the proposed method can achieve accurate parameter estimation with both moderately and highly undersampled data. Although all methods performed fairly well with moderately undersampled data, the proposed method achieved much better performance (e.g., more accurate parameter values) than the other two methods with highly undersampled data. CONCLUSIONS Simultaneously imposing low-rank and sparsity constraints can effectively improve the accuracy of fast MR parameter mapping with sparse sampling.
منابع مشابه
In vivo accelerated MR parameter mapping using annihilating filter - based low rank Hankel matrix ( ALOHA )
The purpose of this study is to develop an accelerated MR parameter mapping technique. For accelerated T1 and T2 mapping, spin-echo inversion recovery and multi-echo spin echo pulse sequences were redesigned to perform undersampling along phase encoding direction. The highly missing k-space were then interpolated by using recently proposed annihilating filter based low-rank Hankel matrix approa...
متن کاملAccelerated parameter mapping with compressed sensing: an alternative to MR fingerprinting
We introduce a method for MR parameter mapping based on three concepts: 1) an inversion recovery, variable flip angle acquisition strategy designed for speed, signal, and contrast; 2) a compressed sensing reconstruction which exploits spatiotemporal correlations through low rank regularization; and 3) a model-based optimization to simultaneously estimate proton density, T1, and T2 values from t...
متن کاملBalancing Sparsity and Rank Constraints in Quadratic Basis Pursuit
We investigate the methods that simultaneously enforce sparsity and low-rank structure in a matrix as often employed for sparse phase retrieval problems or phase calibration problems in compressive sensing. We propose a new approach for analyzing the trade off between the sparsity and low rank constraints in these approaches which not only helps to provide guidelines to adjust the weights betwe...
متن کامل3D Inversion of Magnetic Data through Wavelet based Regularization Method
This study deals with the 3D recovering of magnetic susceptibility model by incorporating the sparsity-based constraints in the inversion algorithm. For this purpose, the area under prospect was divided into a large number of rectangular prisms in a mesh with unknown susceptibilities. Tikhonov cost functions with two sparsity functions were used to recover the smooth parts as well as the sharp ...
متن کاملProspectively accelerated first-pass myocardial perfusion imaging in patients using motion-compensated compressed sensing exploiting regional low-rank sparsity
Background First-pass perfusion CMR utilizes accelerated imaging to achieve high spatial resolution and coverage within a small acquisition window. Several compressed sensing (CS) methods have been proposed to accelerate perfusion imaging. However, patient motion due to imperfect breathholding and other factors leads to degraded quality of CS-reconstructed images. We recently demonstrated a CS ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance in medicine
دوره 74 2 شماره
صفحات -
تاریخ انتشار 2015