Mandibular overdentures retained by two implants: 10-year results from a crossover clinical trial comparing ball-socket and bar-clip attachments.

نویسندگان

  • Marco Cune
  • Mark Burgers
  • Frits van Kampen
  • Cornelis de Putter
  • Andries van der Bilt
چکیده

PURPOSE The aim of this study was to evaluate patient satisfaction and clinical and prosthetic outcomes of two-implant mandibular overdenture treatment with different attachment types after 10 years of function. MATERIALS AND METHODS In a crossover clinical trial, 18 edentulous subjects with complaints regarding their mandibular dentures received two implants and a new denture with magnet, ball-socket, or bar-clip attachments that were applied in a random order. At the end of the experiment, the attachment type of their choosing was fitted in the overdenture. After 10 years, 7 subjects with a ball-socket and 7 subjects with a bar-clip attachment were available for evaluation. The same questionnaire from 10 years before was completed, and subjects were asked to express their overall appreciation of their dentures on a visual analog scale (VAS). Six scales of denture complaints were constructed. Mean scale and VAS scores between initial evaluation and after 10 years were compared. In addition, marginal probing depths, Bleeding Index, and radiographic marginal bone loss were assessed. RESULTS There was no marked difference in satisfaction between subjects with ball-socket- and bar-clip-retained two-implant mandibular overdentures at initial evaluation and after 10 years of function. CONCLUSION Patients' appreciation of their implant-retained denture was and remained high over time. Clinical parameters revealed healthy mucosal conditions and stable marginal bone levels, determined radiographically. Probing depths around implants provided with ball-socket attachments were slightly shallower than those with bar-clip attachments after 10 years of function (P < .05).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Patient satisfaction and preference with magnet, bar-clip, and ball-socket retained mandibular implant overdentures: a cross-over clinical trial.

PURPOSE The purposes of this study were to: (1) determine patient satisfaction with implant-supported mandibular overdentures using magnet, bar-clip, and ball-socket attachments; and (2) assess the relation between maximum bite force and patient satisfaction. MATERIALS AND METHODS In a cross-over clinical trial, 18 edentulous patients with mandibular denture complaints received two mandibular...

متن کامل

Comparison of stresses transferred to the implant supported overdentures with bar, ball and zaag attachments through photoelasticity

Comparison of stresses transferred to the implant supported overdentures with bar, ball and zaag attachments through photoelasticity Dr. A. Saboori* - Dr. Gh. Esfahanizade** - Dr. M. Ejlali*** *- Assistant Professor of Prosthodontics Dept. - Faculty of Dentistry – Shaheed Beheshti University of Medical Sciences. **- Assistant Professor of Prosthodontics Dept. - Faculty of Dentistry – Tehran Isl...

متن کامل

Comparison of the Effect of Ball and Bar Attachment Designs on Retention and Stability of Mandibular Implant-Supported Overdentures

Objectives: The present study evaluated the effect of bar and ball attachment designs on retention and stability of a mandibular overdenture supported by four implants. Methods: An edentulous mandibular acrylic resin model with four implants in the anterior part of the ridge (A, B, D and E) was fabricated. A metal framework simulating the overdenture was also fabricated. Totally, 30...

متن کامل

Two Years Retrospective Evaluation of Overdenture Retained by Symphyseal Single Implant Using Two Types of Attachments

BACKGROUND This study was aimed to evaluate complete mandibular overdentures retained by a symphyseal single implant using ball and magnet attachments in both clinical and radiographic evaluation. MATERIALS AND METHODS Ten dental press fit titanium implants were installed in the lower jaws of completely edentulous patients according to two-stage surgical protocol. For each patient, one implan...

متن کامل

Mandibular implant-retained overdenture: finite element analysis of two anchorage systems.

Transmission of masticatory load in mandibular implant-retained overdentures was evaluated using a three-dimensional finite element model. The reaction forces on the distal edentulous mucosa and the stress on the perimplant bone were compared in overdentures retained either by two ball attachments or by two clips on a bar connecting two implants. In the finite element model, a 35 N load on the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The International journal of prosthodontics

دوره 23 4  شماره 

صفحات  -

تاریخ انتشار 2010