OBJECT This study was performed to evaluate the reliability and utility of using monopolar impedance monitoring for estimation of the location of the thermocouple electrode during a pallidotomy procedure. METHODS In 26 patients, impedance profiles were measured at 2-mm intervals and anatomical boundaries were marked on postoperative MRI studies in 19 patients. The pattern of change in impedance as the electrode was towards the target coordinates in the globus pallidus was studied empirically in relation to MRI-defined anatomy and by electrical stimulations. The pattern of impedance change was of greater reliability than absolute impedance values. A drop in impedance was noted in 10 cases where the electrode entered the putamen or globus pallidus upon exiting the internal capsule, and in 9 of these this drop was measured before or at the distal boundary of the internal capsule. A variable pattern in the region of the base of the globus pallidus was observed, with 10 of 19 cases demonstrating a decrease and 8 cases an increase, consistent with the proximity of a CSF cistern in the former and the ansa lenticularis and optic tract in the latter. Simulations showed that the monopolar electrode was more sensitive to the approach of a boundary than the bipolar electrode. CONCLUSION Our measurements and simulations suggest that a monopolar electrode could predict a nearby region of high or low impedance before penetrating it and a trend of decreasing impedance as the distal edge of the globus pallidus is approached.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Real-time measurement of electrode impedance during intracochlear electrode insertion.

OBJECTIVES/HYPOTHESIS This pilot study details the use of a software tool that uses continuous impedance measurement during electrode insertion, with the eventual potential to assess and optimize electrode position and reduce insertional trauma. STUDY DESIGN Software development and experimental study with human cadaveric cochleae and two live surgeries. METHODS A prototype program to measu...

متن کامل

A prospective randomized comparison of CT and MRI pre-operative localization for pallidotomy.

OBJECTIVE During the pallidotomy procedure, is pre-operative localization with MRI more accurate than CT and does it result in a significant difference in surgical outcome? METHODS Twenty-four Parkinson's Disease patients received a unilateral pallidotomy for their motor symptoms. Dyskinesia was scored pre- and six weeks postoperatively. All patients had a pre-operative CT scan and MRI to cal...

متن کامل

Surface Modification of Glassy Carbon Electrode by Ni-Cu Nanoparticles as a Competitive Electrode for Ethanol Electro-Oxidation

In the present study, Nickel-Copper nanoparticles were electrodeposited on glassy carbon electrode (GCE) by using electroplating deposition method. The prepared electrode was characterized by scanning electron microscopy (SEM) and elemental mapping analysis. Results showed that Ni-Cu nanoparticles with a high density are distributed at the surface of the glassy carbon electrode. Subsequentl...

متن کامل

Dual Switching Monopolar Radiofrequency Ablation Using a Separable Clustered Electrode: Comparison with Consecutive and Switching Monopolar Modes in Ex Vivo Bovine Livers

OBJECTIVE To compare the in-vitro efficiency of dual-switching monopolar (DSM) radiofrequency ablation (RFA) using a separable clustered electrode (Octopus® electrodes) with consecutive monopolar (CM) and switching monopolar (SM) RFA techniques to create an ablative zone in the explanted bovine liver. MATERIALS AND METHODS For DSM-RFA, we used a prototype, three-channel, dual generator RFA Un...

متن کامل

A Comparative Experimental Study of the In-vitro Efficiency of Hypertonic Saline-Enhanced Hepatic Bipolar and Monopolar Radiofrequency Ablation

OBJECTIVE To compare the in-vitro efficiency of a hypertonic saline (HS)-enhanced bipolar radiofrequency (RF) system with monopolar RF applications by assessing the temperature profile and dimensions of RF-created coagulation necrosis in bovine liver. MATERIALS AND METHODS A total of 27 ablations were performed in explanted bovine livers. After placement of two 16-gauge open-perfused electrod...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Stereotactic and functional neurosurgery

دوره 72 1  شماره 

صفحات  -

تاریخ انتشار 1999