Automatic tuning of myoelectric prostheses.

نویسندگان

  • C Bonivento
  • A Davalli
  • C Fantuzzi
  • R Sacchetti
  • S Terenzi
چکیده

This paper is concerned with the development of a software package for the automatic tuning of myoelectric prostheses. The package core consists of Fuzzy Logic Expert Systems (FLES) that embody skilled operator heuristics in the tuning of prosthesis control parameters. The prosthesis system is an artificial arm-hand system developed at the National Institute of Accidents at Work (INAIL) laboratories. The prosthesis is powered by an electric motor that is controlled by a microprocessor using myoelectric signals acquired from skin-surface electrodes placed on a muscle in the residual limb of the subject. The software package, Microprocessor Controlled Arm (MCA) Auto Tuning, is a tool for aiding both INAIL expert operators and unskilled persons in the controller parameter tuning procedure. Prosthesis control parameter setup and subsequent recurrent adjustments are fundamental for the correct working of the prosthesis, especially when we consider that myoelectric parameters may vary greatly with environmental modifications. The parameter adjustment requires the end-user to go to the manufacturer's laboratory for the control parameters setup because, generally, he/she does not have the necessary knowledge and instruments to do this at home. However, this procedure is not very practical and involves a waste of time for the technicians and uneasiness for the clients. The idea behind the MCA Auto Tuning package consists in translating technician expertise into an FLES knowledge database. The software interacts through a user-friendly graphic interface with an unskilled user, who is guided through a step-by-step procedure in the prosthesis parameter tuning that emulates the traditional expert-aided procedure. The adoption of this program on a large scale may yield considerable economic benefits and improve the service quality supplied to the users of prostheses. In fact, the time required to set the prosthesis parameters are remarkably reduced, as is the technician's working time. This is interpreted as minor costs for prostheses manufacturers and suppliers.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Long-term results of early myoelectric prosthesis fittings: A prospective case-control study.

BACKGROUND Different recommendations exist regarding what age is best for first-time fitting of myoelectric hand prostheses in children. OBJECTIVES To compare prosthetic skill, prosthetic use and risk for rejection over time between children fitted with myoelectric hand prostheses before or after 2½ years of age. STUDY DESIGN Prospective case-control design. METHODS The cases were nine ch...

متن کامل

Evidence Note Differences in Myoelectric and Body-Powered Upper Limb Prostheses

Key Points  Research comparing upper limb prostheses is limited.  Body-powered prostheses have demonstrated advantages in durability, training time, user feedback and frequency of adjustment and maintenance.  Myoelectric prostheses have been shown to provide a cosmetic advantage, are more accepted for light intensity work, and may positively affect phantom limb pain when used actively.  Bod...

متن کامل

Chapter 3 Rehabilitation of the Injured Combatant Vol 1 Rehabilitation of the Upper Limb Amputee

INTRODUCTION HAND AMPUTATIONS Hand Amputations and Reconstruction Hand Rehabilitation Hand Prosthetic Devices NOMENCLATURE AND FUNCTIONAL LEVELS PRINCIPLES OF AMPUTATION SURGERY REHABILITATION Early Rehabilitation Postoperative Prosthetic Fitting Activities of Daily Living BELOW ELBOW PROSTHESES Prosthetic Sockets Terminal Devices and Wrist Units Suspension and Control ABOVE-ELBOW PROSTHESES HU...

متن کامل

Learning a Novel Myoelectric-Controlled Interface Task

Control of myoelectric prostheses and brain-machine interfaces requires learning abstract neuromotor transformations. To investigate the mechanisms underlying this ability, we trained subjects to move a two-dimensional cursor using a myoelectric-controlled interface. With the upper limb immobilized, an electromyogram from multiple hand and arm muscles moved the cursor in directions that were ei...

متن کامل

Differences in myoelectric and body-powered upper-limb prostheses: Systematic literature review.

The choice of a myoelectric or body-powered upper-limb prosthesis can be determined using factors including control, function, feedback, cosmesis, and rejection. Although body-powered and myoelectric control strategies offer unique functions, many prosthesis users must choose one. A systematic review was conducted to determine differences between myoelectric and body-powered prostheses to infor...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of rehabilitation research and development

دوره 35 3  شماره 

صفحات  -

تاریخ انتشار 1998