Elimination of field size dependence of enhanced dynamic wedge factors.
نویسندگان
چکیده
Enhanced dynamic wedge factors (EDWF) are characterized by a strong field size dependence. In contrast to physical wedge factors, the EDWF decrease as the field size is increased: for 6 MV 60 degrees wedge, the EDWF decreases by 50% when the field size is increased from 4 x 4 cm2 to 20 x 20 cm2. A method that eliminates the field size dependence of EDWF was developed and investigated in this work. In this method, the wedged field shape is determined by a multileaf collimator. The initial position of the moving Y jaw is determined by the field size and the stationary Y jaw is kept fixed at 10 cm for field sizes < or = 20 cm in the wedged direction. For all other fields, the stationary Y jaw setting is determined by the field size. The modified method results in EDWF that are independent of field size, with no change in the wedge dose distribution when compared with the conventional use of EDW.
منابع مشابه
Assessment of variation of wedge factor with depth, field size and SSD for Neptun 10PC Linac in Mashhad Imam Reza Hospital
Background: In radiotherapy, wedge filters are used for optimizing the tumor dose distribution in patients. The attenuation in beam intensity due to the presence of wedge filter is compensated by means of a wedge factor measured at the central axis of the beam. The field size, depth and SSD dependence of wedge factor have been assessed for 9MV radiations of Neptun PC linear accelerator. Materia...
متن کاملOptimum reckoning of contra lateral breast dose using physical wedge and enhanced dynamic wedge in radiotherapy treatment planning system
Background: It was intended to investigate the effect of physical wedge (PW) and enhanced dynamic wedges (EDW) on contralateral breast dose during primary breast irradiation in radiotherapy treatment, using high energy photon beams. Materials and Methods: The Varian’s Clinac dual mode linear accelerator model 2100 C/D and Siemen’s Primus accelerators were used for radiation doses wi...
متن کاملComparison of dosimetric characteristics of physical and enhanced dynamic wedges.
BACKGROUND Wedge filters can be used as missing tissue compensators or wedge pairs to alter the shape of isodose curves so that two beams can be angled with a small hinge angle at a target volume without creating a hotspot. AIM In this study the dosimetric properties of Varian Enhanced Dynamic Wedge (EDW) and physical wedges (PW) were analyzed and compared. MATERIALS AND METHODS Ionometric ...
متن کاملInvestigation of the Field Size Effect on Wedge Field Isodose Curves Angle for Two Energies; 6 & 18 MV, produced by VARIAN 2100C Linac
Introduction: Nowadays, considerable developments in the field of radiotherapy have been achieved. They include the advances made in the equipments and treatment planning techniques which require highly complex calculations. Such achievements have made it possible to treat cancer patients not only with higher radiation dose but also with higher precision and con...
متن کاملDosimetric evaluation of a treatment planning system using pencil beam convolution algorithm for enhanced dynamic wedges with symmetric and asymmetric fields
Background: The dosimetric performance of Eclipse 6.5 three dimensional treatment planning system (3DTPS) is evaluated by comparing the calculated and measured dose in two dimensions following the guide lines of American Association for Physicists in Medicine Task Group 53. Materials and Methods: The calculations were performed by the 3DTPS for symmetric as well as asymmetric fields for standar...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Physics in medicine and biology
دوره 45 11 شماره
صفحات -
تاریخ انتشار 2000