Optimisation and validation of the analytical procedure for the determination of acrylamide in coffee by LC-MS/MS with SPE clean up.
نویسندگان
چکیده
BACKGROUND Numerous studies have demonstrated acrylamide to be both neurotoxic and carcinogenic. At present it is widely recognised that acrylamide is mainly formed through the Maillard reaction from free asparagine and reducing sugars. The major sources of dietary acrylamide are potato products, processed cereals and coffee. OBJECTIVE To optimise and validate an analytical method for determining acrylamide in coffee by liquid chromatography and tandem mass spectrometry analysis (LC/MS/MS) using SPE clean-up. MATERIAL AND METHODS Analytical separation of acrylamide from roasted coffee was performed by liquid chromatography using a Hypercarb column followed by LC/MS/MS analysis, with 2,3,3-d3 acrylamide as an internal standard. The method was based on two purification steps: the first with hexane and Carrez solutions in order to remove of fat and to precipitate proteins, respectively; and the second with a solid-phase extraction (SPE) column which proved to be efficient in the elimination of the main chromatographic interferences. RESULTS Limit of quantification (LOQ) for measuring acrylamide in coffee was 50 microg/kg. The described method demonstrates satisfactory precision (RSD = 2.5%), repeatability (RSD = 9.2%) and accuracy (mean recovery - 97.4%). CONCLUSIONS Our results confirm that LC-MS/MS with SPE clean-up is selective and suitable for determination of acrylamide in coffee. Indeed, this method meets the criteria of EU Commission Recommendations (No. 2007/331/EC and No. 2010/307/EU), on the monitoring of acrylamide levels in food.
منابع مشابه
Automated Solid Phase Extraction (SPE)-LC-MS/MS Method for the Determination of Acrylamide in Brewed Coffee Samples
Acrylamide is thought to be produced during the roasting process associated with coffee production. Acrylamide has been labeled as a probable human carcinogen. Due to the use of roasted coffee beans in making coffee and the high consumption of coffee world-wide, brewed coffee could be a source of daily exposure to acrylamide. Acrylamide determination has been shown to be challenging due to pres...
متن کاملValidation of the analysis method of 25 pesticide residues in rice using LC-MS/MS device (liquid chromatography-mass spectrometry)
Introduction: In recent years, due to the increase in the use of pesticides in agricultural products and its entry into the human food chain, there has been an increase in concerns about the health of food among people. Therefore, the purpose of conducting this research is to validate the analysis method. 25 pesticide residues in rice using LC-MS/MS. Methods: In this research, a simultaneous an...
متن کاملDetermination of acrylamide in coffee and coffee products by GC-MS using an improved SPE clean-up.
An improved gas chromatography-mass spectrometry (GC-MS) method to determine acrylamide (AA) in coffee and coffee products was developed. The method was based on two main purification steps: the first with ethanol and Carrez solutions in order to precipitate polysaccharides and proteins, respectively; and the second with a layered solid-phase extraction (SPE) column which proved to be efficient...
متن کاملMethod validation of methotrexate in human plasma by LC-MS technique in patients with brain tumor.
Background and aims: A selective and sensitive high performance liquid chromatography-electrospray ionization mass spectrometry method has been established for determination of methotrexate in human plasma. Methods: Methotrexate was extracted from plasma with acetonitrile. The mobile phase consisted of acetonitrile-water-formic acid 74: 25: 1(v/v). Twenty...
متن کاملDevelopment of Isotope Dilution-Liquid Chromatography/Tandem Mass Spectrometry as a Candidate Reference Method for the Determination of Acrylamide in Potato Chips
An isotope dilution-liquid chromatography/tandem mass spectrometric method was developed as a candidate reference method for the accurate determination of acrylamide in potato chips, starch-rich foodstuff cooked at high temperature. Sample was spiked with C3-acrylamide and then extracted with water. The extract was further cleaned up with an Oasis HLB solid-phase extraction (SPE) cartridge and ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Roczniki Panstwowego Zakladu Higieny
دوره 64 2 شماره
صفحات -
تاریخ انتشار 2013