Intraobserver and interobserver reliability of radial torsion angle measurements by a new and alternative method with computed tomography

نویسندگان

  • Luiz Fernando Pinheiro de Freitas
  • Cláudio Henrique Barbieri
  • Nilton Mazzer
  • Salomão Chade Assan Zatiti
  • Ângela Delete Bellucci
  • Marcello Henrique Nogueira‐Barbosa
چکیده

OBJECTIVE To evaluate the intraobserver and interobserver reliability of radial torsion angle measurement using computed tomography. METHODS Twelve pairs of cadaver radii and 116 forearms from 58 healthy volunteers were evaluated using axial computed tomography sections measured at the level of the bicipital tuberosity and the subchondral region of the radius. During digital imaging, the angle was formed by two lines, one diametrically perpendicular to the radial tubercle and the other tangential to the volar rim of the distal joint surface. Measurements were performed twice each by three observers. RESULTS In cadaveric bones, the mean radial torsion angle was 1.48º (-6º - 9º) on the right and 1.62º (-6 º - 8º) on the left, with a mean difference between the right and left sides of 1.61º (0º - 8º). In volunteers, the mean radial torsion angle was 3.00° (-17° - 17°) on the right and 2.91° (-16°- 15°) on the left, with a mean difference between the sides of 1.58º (0º - 7º). There was no significant difference between each side. The interobserver correlation coefficient for the cadaver radii measurements was 0.88 (0.72 - 0.96) and 0.81 (0.58 - 0.93) for the right and left radius, respectively, while for the volunteers, the difference was 0.84 (0.77 - 0.90) and 0.83 (0.75 - 0.89), respectively. Intraobserver reliability was high. CONCLUSION The described method is reproducible and applicable even when the radial tubercle has a rounded contour.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The interobserver and intraobserver reliability of the Fernandez classification of distal radius fracture

 Abstract Background: With increasing knowledge concerning fractures of the distal radius, different classifications have been proposed. Reliability of most of these classifications has been assessed. The Fernandez classification has never been assessed for intraobserver and interobserver reliability, although this classification is commonly used. Methods: Five observers including one attending...

متن کامل

Intra and Interobserver Reliability and Agreement of Semiquantitative Vertebral Fracture Assessment on Chest Computed Tomography

OBJECTIVES To evaluate the reliability of semiquantitative Vertebral Fracture Assessment (VFA) on chest Computed Tomography (CT). METHODS Four observers performed VFA twice upon sagittal reconstructions of 50 routine clinical chest CTs. Intra- and interobserver agreement (absolute agreement or 95% Limits of Agreement) and reliability (Cohen's kappa or intraclass correlation coefficient(ICC)) ...

متن کامل

A Survey on Current Methods of Carpal Height Ratio Measurement and Suggestion of a New Method

Background & Aims: Two famous methods are commonly used for the measurement of carpal height ratio. Both methods are performed on anteroposterior radiogram and have some shortcomings. We are going to introduce a new method for measuring this index in lateral view of the wrist radiogram' Methods: This cross-sectional and case-control study was conducted on 100 anteroposterior and lateral radiogr...

متن کامل

Evaluation of cephalometric landmark identification on CBCT multiplanar and 3D reconstructions.

OBJECTIVE To evaluate the reliability of three-dimensional (3D) landmark identification in cone-beam computed tomography (CBCT) using two different visualization techniques. MATERIALS AND METHODS Twelve CBCT images were randomly selected. Three observers independently repeated three times the identification of 30 landmarks using 3D reconstructions and 28 landmarks using multiplanar views. The...

متن کامل

Cervical pedicle morphometry in a Latin American population

The goal of this study was to conduct a detailed computed tomography (CT) assessment in the Brazilian population of the screw starting point, trajectory, and dimensions of pedicle in the cervical spine.Two hundred consecutive patients were retrospectively evaluated using cervical spine CT, with imaging reconstruction of each cervical vertebrae in the axial plane with 2 mm, and in sagittal recon...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 65  شماره 

صفحات  -

تاریخ انتشار 2010