Bone-subtraction CT angiography: evaluation of two different fully automated image-registration procedures for interscan motion compensation.
نویسندگان
چکیده
BACKGROUND AND PURPOSE Bone-subtraction techniques have been shown to enhance CT angiography (CTA) interpretation, but motion can lead to incomplete bone removal. The aim of this study was to evaluate 2 novel registration techniques to compensate for patient motion. MATERIALS AND METHODS Fifty-four patients underwent bone-subtraction CTA (BSCTA) for the evaluation of the neck vessels with 64-section CT. We tested 3 different registration procedures: pure rigid registration (BSCTA), slab-based registration (SB-BSCTA), and a partially rigid registration (PR-BSCTA) approach. Subtraction quality for the assessment of different vascular segments was evaluated by 2 examiners in a blinded fashion. The Cohen kappa test was applied for interobserver variability, and the Wilcoxon signed rank test, for differences between the procedures. Motion between the corresponding datasets was measured and plotted against image-quality scores. RESULTS Algorithms with motion compensation revealed higher image-quality scores (SB-BSCTA, mean 4.31; PR-BSCTA, mean 4.43) than pure rigid registration (BSCTA, mean 3.88). PR-BSCTA was rated superior to SB-BSCTA for the evaluation of the cervical internal and external carotid arteries (P<.001), whereas there was no significant difference for the other vessels (P=.157-.655). Both algorithms were clearly superior to pure rigid registration for all vessels except the basilar and ophthalmic artery. Interobserver agreement was high (kappa=0.46-0.98). CONCLUSION Bone-subtraction algorithms with motion compensation provided higher image-quality scores than pure rigid registration methods, especially in cases with complex motion. PR-BSCTA was rated superior to SB-BSCTA in the visualization of the internal and external carotid arteries.
منابع مشابه
Motion Detection and Motion Compensation for Digital Subtraction Angiography Image Enhancement
For the enhancement of digital subtraction angiography (DSA) images, registration of mask and contrast image prior to subtraction is a prerequisite. One of the main requirements of this task is that the region-ofinterest used for the calculation of the registration parameters should contain the vascular structures of interest. This, however, is also one of the main problems in DSA because the c...
متن کاملAutomatic Segmentation of Vertebral Arteries in Head and Neck CT Angiography Images
Computed tomography (CT) angiography is a useful imaging technique for the evaluation of the intraand extra-cranial vasculature. With the introduction of multi-detector row CT scanners, head and neck CT angiography images make it easy to detect cerebral aneurysms, arterial stenosis, and other vascular anomalies. To get an arterial anatomy in three-dimensional views, CT angiography images are of...
متن کاملMotion compensated digital subtraction angiography
Digital subtraction angiography, whether based on traditional X-ray or MR, su ers from patient motion artifacts. Until now, the usual remedy is to pixel shift by hand, or in some cases performing a global pixel shift semi-automatically. This is time consuming, and cannot handle rotations or local varying deformations over the image. We have developed a fully automatic algorithm that provides fo...
متن کاملImprovement of Vessel Segmentation by Elastically Compensated Patient Motion in Digital Subtraction Angiography Images
Digital subtraction angiography is a standard diagnosis tool for the examination of vessels. For this method X-ray images (contrast images) are taken from the patient while a radio-opaque contrast agent is injected through a catheter. The first image of such a scene is usually taken before injection and is called mask image. In clinical routine the mask image is manually shifted to perform a ro...
متن کاملDigital subtraction CT angiography based on efficient 3D registration and refinement.
A novel method for fast, automatic 3D digital subtraction CT angiography (DS-CTA) is presented to generate artifact-free angiograms. The proposed method consists of two steps: 3D registration to align a CT image to the CT angiography (CTA) image and subtraction-and-refinement to extract blood vessels only. For efficient and accurate 3D registration in the first step, an normalized mutual inform...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 28 7 شماره
صفحات -
تاریخ انتشار 2007