Reference standardization and triglyceride interference of a new homogeneous HDL-cholesterol assay compared with a former chemical precipitation assay.

نویسندگان

  • C Cobbaert
  • L Zwang
  • F Ceriotti
  • A Modenese
  • P Cremer
  • W Herrmann
  • G Hoss
  • J Jarausch
  • R Türk
  • W März
  • M Nauck
چکیده

A homogeneous HDL-c assay (HDL-H), which uses polyethylene glycol-modified enzymes and sulfated alpha-cyclodextrin, was assessed for precision, accuracy, and cholesterol and triglyceride interference. In addition, its analytical performance was compared with that of a phosphotungstic acid (PTA)/MgCl2 precipitation method (HDL-P). Within-run CVs were < or = 1.87%; total CVs were < or = 3.08%. Accuracy was evaluated in fresh normotriglyceridemic sera using the Designated Comparison Method (HDL-H = 1.037 Designated Comparison Method + 4 mg/L; n = 63) and in moderately hypertriglyceridemic sera by using the Reference Method (HDL-H = 1.068 Reference Method - 17 mg/L; n = 41). Mean biases were 4.5% and 2.2%, respectively. In hypertriglyceridemic sera (n = 85), HDL-H concentrations were increasingly positively biased with increasing triglyceride concentrations. The method comparison between HDL-H and HDL-P yielded the following equation: HDL-H = 1.037 HDL-P + 15 mg/L; n = 478. We conclude that HDL-H amply meets the 1998 NCEP recommendations for total error; its precision is superior compared with that of HDL-P, and its average bias remains below +/-5% as long as triglyceride concentrations are < or = 10 g/L and in case of moderate hypercholesterolemia.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of a homogeneous assay with a precipitation method for the measurement of HDL cholesterol in diabetic patients.

OBJECTIVE To compare direct-measured HDL cholesterol with HDL cholesterol measured by a precipitation method. RESEARCH DESIGN AND METHODS We compared a homogeneous assay for direct HDL cholesterol analysis with the phosphotungstic acid magnesium chloride precipitation method in 55 type 1 diabetic patients, 70 type 2 diabetic patients, and 82 nondiabetic normal control subjects with plasma tri...

متن کامل

Survey of total error of precipitation and homogeneous HDL-cholesterol methods and simultaneous evaluation of lyophilized saccharose-containing candidate reference materials for HDL-cholesterol.

BACKGROUND Standardization of HDL-cholesterol is needed for risk assessment. We assessed for the first time the accuracy of HDL-cholesterol testing in The Netherlands and evaluated 11 candidate reference materials (CRMs). METHODS The total error (TE) of HDL-cholesterol measurements was assessed in native human sera by 25 Dutch clinical chemistry laboratories. Concomitantly, the suitability of...

متن کامل

Multicenter evaluation of a homogeneous assay for HDL-cholesterol without sample pretreatment.

We evaluated a new homogeneous assay for the measurement of HDL-cholesterol (HDL-C) in six European laboratories. The assay includes two reagents and is applicable to most autoanalyzers, which allows full automation. The total CVs of the new method ranged between 1.3% and 6.7%. Thereby determined HDL-C values were in good agreement with those obtained by precipitation with phosphotungstic acid/...

متن کامل

New immunoseparation-based homogeneous assay for HDL-cholesterol compared with three homogeneous and two heterogeneous methods for HDL-cholesterol.

We evaluated four new commercial methods for HDL-cholesterol determination. The three completely homogeneous assays were an immunoseparation-based (IS) method from Wako, a polyethylene glycol-modified enzyme (PEG) method from Boehringer Mannheim, and a synthetic polymer-based (SP) method from Genzyme. The fourth method was a new heterogeneous method in which lipoproteins are removed using dextr...

متن کامل

Three routine methods for measuring high-density lipoprotein cholesterol compared with the Reference Method.

We compared the performance of three methods for quantifying high-density lipoprotein cholesterol (HDL-C) with the Reference Method for HDL-C, using samples with a wide range of triglyceride (TG) concentrations (290-18000 mg/L). All three comparison assays-- utilizing a magnetic dextran sulfate precipitating reagent, a direct method, and a standard MgCl2-dextran sulfate reagent--were precise, w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 44 4  شماره 

صفحات  -

تاریخ انتشار 1998