Chemically activated luciferase gene expression (CALUX) cell bioassay analysis for the estimation of dioxin-like activity: critical parameters of the CALUX procedure that impact assay results.

نویسندگان

  • Isabelle Windal
  • Michael S Denison
  • Linda S Birnbaum
  • Nathalie Van Wouwe
  • Willy Baeyens
  • Leo Goeyens
چکیده

The chemically activated luciferase gene expression (CALUX) in vitro cell bioassay is a bioanalytical tool that is increasingly being used by research and commercial laboratories for the screening and relative quantification of dioxins and dioxin-like compounds in sample extracts. Since CALUX analyses provide a biological response to all aryl hydrocarbon receptor active compounds present in a given sample extract containing a complex mixture of chemicals, interpretation of results is significantly more complexthan of chemical analyses. Operators in the laboratory can adjust many parameters when performing CALUX analyses, and the applied procedure strongly affects the result and, hence, the interpretation of the results. This paper examines critical methodological parameters and aspects of the CALUX bioassay that can affect the quality and accuracy of the analyses. Moreover, the study aims to identify the ways that alteration of these parameters influences CALUX measurements. A greater understanding of these characteristics will lead to increased accuracy, precision, and reproducibility of the widely used CALUX bioassay within and between research laboratories.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Considerations for potency equivalent calculations in the Ah receptor-based CALUX bioassay: normalization of superinduction results for improved sample potency estimation.

The chemically activated luciferase expression (CALUX) system is a mechanistically based recombinant luciferase reporter gene cell bioassay used in combination with chemical extraction and clean-up methods for the detection and relative quantitation of 2,3,7,8-tetrachlorodibenzo-p-dioxin and related dioxin-like halogenated aromatic hydrocarbons in a wide variety of sample matrices. While sample...

متن کامل

Third-generation Ah receptor-responsive luciferase reporter plasmids: amplification of dioxin-responsive elements dramatically increases CALUX bioassay sensitivity and responsiveness.

2,3,7,8-Tetrachlorodibenzo-p-dioxin (TCDD, dioxin) and related dioxin-like chemicals are widespread and persistent environmental contaminants that produce diverse toxic and biological effects through their ability to bind to and activate the Ah receptor (AhR) and AhR-dependent gene expression. The chemically activated luciferase expression (CALUX) system is an AhR-responsive recombinant lucifer...

متن کامل

Analysis of PCDD/Fs and dioxin-like PCBs in atmospheric deposition samples from the Flemish measurement network: correlation between the CALUX bioassay and GC-HRMS.

Since the CALUX (Chemically Activated LUciferase gene eXpression) bioassay is a fast, sensitive and inexpensive tool for the analysis of a high number of samples, the use of this technique in routine analysis of atmospheric deposition samples may be a valuable alternative for GC-HRMS. In this study, a validated CALUX method was used for the analysis of PCDD/Fs and dioxin-like PCBs in more than ...

متن کامل

Dioxin and dioxin-like activity in sediments of the Belgian coastal area (Southern North Sea).

Dioxin and dioxin-like activity in sediments of the North Sea, along the Belgian coast, was assessed with the bioassay CALUX (Chemically Activated LUciferase gene eXpression). Crude extracts of the samples as well as the dioxin fraction (PCDD/Fs) obtained after a thorough clean-up procedure were analyzed with the CALUX method. When analyzing the cleaned extract, a general low contamination leve...

متن کامل

Comparison of chemical-activated luciferase gene expression bioassay and gas chromatography for PCB determination in human serum and follicular fluid.

We assessed exposure to dioxin-like compounds using chemical and bioassay analysis in different matrices in a female population. A total of 106 serum and 9 follicular fluid samples were collected from infertile women attending Centers for Reproductive Medicine in Belgium from 1996 to 1998. Major polychlorinated biphenyl (PCB) congeners were quantified by chemical analysis using gas chromatograp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Environmental science & technology

دوره 39 19  شماره 

صفحات  -

تاریخ انتشار 2005