Long-term follow-up of sacrocolpopexy mesh implants at two time intervals at least 1 year apart using 4D transperineal ultrasound.

نویسندگان

  • V H Eisenberg
  • M Steinberg
  • Z Weiner
  • E Schiff
  • L Lowenstein
چکیده

OBJECTIVE To determine, using four-dimensional (4D) transperineal ultrasound, whether the appearance, position or dimensions of sacrocolpopexy mesh implants or the degree of tissue support change in the long term. METHODS Women who had undergone minimally invasive abdominal sacrocolpopexy for pelvic organ prolapse were invited for follow-up assessment at two consecutive visits at least 1 year apart. All participants completed a Pelvic Floor Distress Inventory questionnaire (PFDI-20) and underwent a pelvic examination by one examiner and had 4D ultrasound volumes obtained by a different examiner. Volumes were analyzed offline for mesh position with the woman at rest and on maximal Valsalva maneuver, and for mesh dimensions and characteristics on three-dimensional orthogonal planes and rendered views, with the operator blinded to the clinical data. Findings were compared between the two examinations. RESULTS Thirty women attended follow-up assessment at two time points, a median of 22 (range, 12-37) months apart. The median age at the latter visit was 60 (range, 46-72) years, median body mass index was 25.9 (range, 20.8-31.9) kg/m2 , median parity was 3 (range, 1-7) and median time from surgery to first and second visit, respectively, was 11.2 (range, 6-26) months and 33.5 (range, 14-56) months. There were no significant differences between the two time points in symptom scores, reported satisfaction from surgery, pelvic examination findings or pelvic organ descent in any compartment according to ultrasound. While mesh dimensions of anterior and posterior arms did not change significantly over time, both arms descended less on Valsalva at the second follow-up compared with at the first (13.2 ± 6.7 mm vs 21.9 ± 10.0 mm and 9.1 ± 5.3 mm vs 16.1 ± 8.1 mm, respectively, both P < 0.001). There were no mesh erosions, but folding remained a consistent finding, occurring in 80% of women in each assessment. CONCLUSIONS Characteristics of tissue support and dimensions of sacrocolpopexy mesh implants remained constant over long-term follow-up, with no mesh shrinkage or erosion. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of the durability of robot-assisted laparoscopic sacrocolpopexy for treatment of vaginal vault prolapse

Transabdominal sacrocolpopexy has been shown, in multiple long-term studies of its success and durability, to be the definitive treatment option for post-hysterectomy vaginal vault prolapse. It is, however, associated with greater morbidity than vaginal repair. We describe a minimally invasive technique for vaginal vault prolapse repair and present our experience with a minimum of one-year foll...

متن کامل

Subjective and objective outcomes 1 year after robotic-assisted laparoscopic sacrocolpopexy.

We aimed to assess the subjective and objective outcomes 1 year after robotic sacrocolpopexy using a type I polypropylene mesh. This was a case series of 64 patients who underwent a robotic-assisted laparoscopic sacrocolpopexy using a type I monofilament polypropylene mesh coated with hydrophilic porcine collagen. Objective and subjective outcomes were assessed using the pelvic organ prolapse q...

متن کامل

Long-term outcomes of robotic mesh sacrocolpopexy.

The aim of the study is to evaluate anatomic and functional late-term outcomes of robotic mesh sacrocolpopexy (RMS) at a single tertiary-care institution. Following IRB approval, a retrospective chart review of a prospectively collected database on consecutive patients who underwent RMS for symptomatic pelvic organ prolapse and had 3 year minimum follow-up was performed. Data collected included...

متن کامل

Long-term outcomes following abdominal sacrocolpopexy for pelvic organ prolapse.

IMPORTANCE More than 225 000 surgeries are performed annually in the United States for pelvic organ prolapse (POP). Abdominal sacrocolpopexy is considered the most durable POP surgery, but little is known about safety and long-term effectiveness. OBJECTIVES To describe anatomic and symptomatic outcomes up to 7 years after abdominal sacrocolpopexy, and to determine whether these are affected b...

متن کامل

Long-term outcomes after robotic sacrocolpopexy in pelvic organ prolapse: prospective analysis.

OBJECTIVE To evaluate the feasibility and long-term outcomes of our initial series of robot-assisted laparoscopic sacrocolpopexy. METHODS We conducted a prospective analysis of our series of robotic sacrocolpopexy. INCLUSION CRITERIA patients with grades III and IV cystocele and or other symptomatic pelvic organ prolapse. We performed a transperitoneal four-trocar technique with the Da Vinc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology

دوره 49 3  شماره 

صفحات  -

تاریخ انتشار 2017