Simple, rapid, kinetic method for serum creatinine measurement.

نویسندگان

  • J A Lustgarten
  • R E Wenk
چکیده

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An enzymic, reaction-rate assay for serum creatinine with a centrifugal analyzer.

We describe a procedure for specific, rapid, kinetic determination of creatinine, in which a manual coupled-enzyme micro-scale assay is adapted to a centrifugal analyzer. The creatinine reaction is ultimately linked to NADH utilization, which is measured by the absorbance change at 340 nm. This procedure requires 15 microL of serum and the standard curve is linear to a creatinine concentration ...

متن کامل

A solution to the problem of bilirubin interference with the kinetic Jaffé method for serum creatinine.

We measured bilirubin interference with the kinetic Jaffé method for serum creatinine. Both pooled sera with added bilirubin and icteric patients' sera were used and results with of which gave more nearly "true" values.

متن کامل

Liquid-chromatographic measurement of creatinine in serum and urine.

We describe the adaptation of a "high-performance" liquid chromatographic method for determination of creatinine in serum and urine. The proposed method is simple, rapid, precise, and accurate. The retention time for creatinine can be varied simply by changing the KH2PO4 concentration in the mobile phase: acetonitrile/aqueous KH2PO4 (1/4 by vol). Within-day precision (CV) was 1.2-3.6% in serum ...

متن کامل

Kinetic serum creatinine assays. II. A critical evaluation and review.

We have evaluated the Technicon AutoAnalyzer method, the Beckman Creatinine Analyzer II, DuPont aca, Electro-Nucleonics GEMSAEC, and Instrumentation Laboratory Model 916 kinetic methods for determination of serum creatinine. These methods, which involve the Jaffé reaction, all showed a statistically significant proportional error relative to an ion-exchange pretreatment method for creatinine in...

متن کامل

Kinetic enzymatic method for determining serum creatinine.

Creatinine amidohydrolase is used to measure serum creatinine in a totally enzymatic procedure. Creatine, produced by hydrolysis, is acted upon by creatine kinase, and then by pyruvate kinase and lactate dehydrogenase, to result in a change in absorbance at 340 nm. The amount of creatinine present is related to the rate of change in A340 and is determined from a standard curve. Absorbance and c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 18 11  شماره 

صفحات  -

تاریخ انتشار 1972