Strain Distribution in a Kennedy Class I Implant Assisted Removable Partial Denture under Various Loading Conditions
نویسندگان
چکیده
Purpose. This in vitro study investigates how unilateral and bilateral occlusal loads are transferred to an implant assisted removable partial denture (IARPD). Materials and Methods. A duplicate model of a Kennedy class I edentulous mandibular arch was made and then a conventional removable partial denture (RPD) fabricated. Two Straumann implants were placed in the second molar region, and the prosthesis was modified to accommodate implant retained ball attachments. Strain gages were incorporated into the fitting surface of both the framework and acrylic to measure microstrain ( μ Strain). The IARPD was loaded to 120Ns unilaterally and bilaterally in three different loading positions. Statistical analysis was carried out using SPSS version 18.0 (SPSS, Inc., Chicago, IL, USA) with an alpha level of 0.05 to compare the maximum μ Strain values of the different loading conditions. Results. During unilateral and bilateral loading the maximum μ Strain was predominantly observed in a buccal direction. As the load was moved anteriorly the μ Strain increased in the mesial area. Unilateral loading resulted in a twisting of the structure and generated a strain mismatch between the metal and acrylic surfaces. Conclusions. Unilateral loading created lateral and vertical displacement of the IARPD. The curvature of the dental arch resulted in a twisting action which intensified as the unilateral load was moved anteriorly.
منابع مشابه
Case Report: Implant-Supported Removable Partial Denture In A Mandibular Kennedy CL II: A Clinical Report
Abstract The implant-supported removable partial dentures should be an alternative to conventional removable partial dentures and implant-supported fixed partial prostheses when the implant’s insertion is confined by bone height and thickness. Placing a single implant in the posterior region would modify the Kennedy Class II configuration to a Kennedy Class III and increase the stability a...
متن کاملStress Distribution in Natural Tooth and Implant Supported Removable Partial Denture with Different Attachment Types: A Photoelastic Analysis
Background and Aim: Different attachment designs have been developed to connect implant to natural teeth in partial dentures; however, adequate studies have not been performed to determine stress distribution patterns in these designs. The present study aimed to assess stress distribution patterns in natural tooth and implant supported removable partial denture with different attachment designs...
متن کاملImplant-assisted removable partial denture: An approach to switch Kennedy Class I to Kennedy Class III
The Kennedy Class I and II distal extension situation poses a challenge to the prosthodontist as it inherently possesses a lack of stability, which may be attributed to the difference in compressibility of the mucosa and the periodontal ligament surrounding the distal-most abutment tooth. This results in a rotational tendency of the prosthesis around the line connecting its terminal abutments. ...
متن کاملMandibular Kennedy Class I implant-tooth-borne removable partial denture: a systematic review.
The purpose of this systematic review is to evaluate the use of implant-tooth-borne removable partial dentures in prosthetic rehabilitation of Kennedy Class I partially edentulous arches. A comprehensive search was performed in MEDLINE, EMBASE, Cochrane Oral Health Group's Trials Register, Cochrane Central Register of Controlled Trials, UK National Research Register, Australian New Zealand Clin...
متن کاملReview of Implant Support for the Distal Extension Removable Partial Dentures
Partially edentulous patients with missing premolars and molars have been conventionally rehabilitated using the free-end removable partial dentures (RPDs). With the advancements in implant dentistry, the benefits of implant-retained/supported mandibular implant overdentures relative to conventional mandibular dentures with bilateral extensions (Class I Kennedy) have now been extensively invest...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
دوره 2013 شماره
صفحات -
تاریخ انتشار 2013