Vacuum-mixing cement does not decrease overall porosity in cemented femoral stems: an in vitro laboratory investigation.
نویسندگان
چکیده
The role of vacuum mixing on the reduction of porosity and on the clinical performance of cemented total hip replacements remains uncertain. We have used paired femoral constructs prepared with either hand-mixed or vacuum-mixed cement in a cadaver model which simulated intra-operative conditions during cementing of the femoral component. After the cement had cured, the distribution of its porosity was determined, as was the strength of the cement-stem and cement-bone interfaces. The overall fraction of the pore area was similar for both hand-mixed and vacuum-mixed cement (hand 6%; vacuum 5.7%; paired t-test, p = 0.187). The linear pore fractions at the interfaces were also similar for the two techniques. The pore number-density was much higher for the hand-mixed cement (paired t-test, p = 0.0013). The strength of the cement-stem interface was greater with the hand-mixed cement (paired t-test, p = 0.0005), while the strength of the cement-bone interface was not affected by the conditions of mixing (paired t-test, p = 0.275). The reduction in porosity with vacuum mixing did not affect the porosity of the mantle, but the distribution of the porosity can be affected by the technique of mixing used.
منابع مشابه
Evaluation of a new power-operated PMMA vacuum mixing and delivery system for cemented femoral stem insertion.
Variations exist in the manual preparationand delivery of cement during primary total hip arthroplasty. The incorporation of a power source may standardize cement mantle manufacturing. This study prospectively compared the use of a new power-operated polymethylmethacrylate vacuum mixing and delivery system to a commonly used manually powered industry standard. The study did not reveal a signifi...
متن کاملThe effect of vacuum mixing and pre-heating the femoral component on the mechanical properties of the cement mantle.
We investigated the effect of pre-heating a femoral component on the porosity and strength of bone cement, with or without vacuum mixing used for total hip replacement. Cement mantles were moulded in a manner simulating clinical practice for cemented hip replacement. During polymerisation, the temperature was monitored. Specimens of cement extracted from the mantles underwent bending or fatigue...
متن کاملPre-heating of components in cemented total hip arthroplasty.
Fatigue fractures which originate at stress-concentrating voids located at the implant-cement interface are a potential cause of septic loosening of cemented femoral components. Heating of the component to 44 degrees C is known to reduce the porosity of the cement-prosthesis interface. The temperature of the cement-bone interface was recorded intra-operatively as 32.3 degrees C. A simulated fem...
متن کاملA ported, proximally-cemented femoral stem for total hip arthroplasty. Development and clinical application.
We describe the development and early clinical application of a ported, proximally-cemented titanium stem for cemented total hip arthroplasty. PMMA bone cement is delivered to the proximal femur under pressure after the stem has been positioned within the femoral canal. A mid-stem cement occluder contains the cement to the proximal stem only. A tapered body is incorporated in the design of the ...
متن کاملEffects of preparation techniques on the porosity of acrylic cements.
We investigated four acrylic cement preparation techniques for their effects on cement porosity: hand mixing, pressurization in a pneumatic pistol, centrifugation, and vacuum mixing. All the techniques were tested on three types of cement with different viscosity characteristics. The best results were obtained with vacuum mixing using a newly designed experimental system, yielding porosity redu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of bone and joint surgery. British volume
دوره 89 8 شماره
صفحات -
تاریخ انتشار 2007