Effect of the dialysis fluid buffer on peritoneal membrane function in children.
نویسندگان
چکیده
BACKGROUND AND OBJECTIVES Double-chamber peritoneal dialysis fluids exert less toxicity by their neutral pH and reduced glucose degradation product content. The role of the buffer compound (lactate and bicarbonate) has not been defined in humans. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS A multicenter randomized controlled trial in 37 children on automated peritoneal dialysis was performed. After a 2-month run-in period with conventional peritoneal dialysis fluids, patients were randomized to neutral-pH, low-glucose degradation product peritoneal dialysis fluids with 35 mM lactate or 34 mM bicarbonate content. Clinical and biochemical monitoring was performed monthly, and peritoneal equilibration tests and 24-hour clearance studies were performed at 0, 3, 6, and 10 months. RESULTS No statistically significant difference in capillary blood pH, serum bicarbonate, or oral buffer supplementation emerged during the study. At baseline, peritoneal solute equilibration and clearance rates were similar. During the study, 4-hour dialysis to plasma ratio of creatinine tended to increase, and 24-hour dialytic creatinine and phosphate clearance increased with lactate peritoneal dialysis fluid but not with bicarbonate peritoneal dialysis fluid. Daily net ultrafiltration, which was similar at baseline (lactate fluid=5.4±2.6 ml/g glucose exposure, bicarbonate fluid=4.9±1.9 ml/g glucose exposure), decreased to 4.6±1.0 ml/g glucose exposure in the lactate peritoneal dialysis fluid group, whereas it increased to 5.1±1.7 ml/g glucose exposure in the bicarbonate content peritoneal dialysis fluid group (P=0.006 for interaction). CONCLUSIONS When using biocompatible peritoneal dialysis fluids, equally good acidosis control is achieved with lactate and bicarbonate buffers. Improved long-term preservation of peritoneal membrane function may, however, be achieved with bicarbonate-based peritoneal dialysis fluids.
منابع مشابه
مقایسه سلولهای مزانشیمی مغز استخوان و سلولهای مزوتلیومی مایع سروزی ازنظر میزان بیان مولکولهای کمپلکس سازگاری نسجی اصلی (MHC)
Abstract Background: Mesothelium is composed of a single layer of mesothelial cells attached to a thin basement membrane supported by subserosal connective tissue it plays an important role in homeostasis, wound healing, fluid transport and inflammation. The introduction of peritoneal dialysis (PD) as a modality of renal replacement therapy has provoked much interest in the biology of perito...
متن کاملComparison of Marital Satisfaction in Hemodialysis and Peritoneal Dialysis Patients
Alternative kidney treatments, including renal transplantation, hemodialysis (HD), and peritoneal dialysis (PD), are administered when severe kidney failure occurs and the kidney can no longer function. The present study compares different dimensions of marital satisfaction in HD and PD patients so as to assist physicians and patients in choosing their appropriate treatment. This cross-se...
متن کاملSpirometric Parameters: Hemodialysis Compared to Peritoneal Dialysis
Introduction: Renal failure affects the mechanical and the ventilatory function of the lungs. A few studies have evaluated the ventilatory and pulmonary function in dialysis patients. The present study aimed to compare Pulmonary Function Test (PFT) results in patients undergoing Hemodialysis (HD) and Peritoneal Dialysis (PD). Materials and Methods: We conducted a cross-sectional study on 50 pa...
متن کاملThe mesothelium under the siege of dialysis solutions: old glucose, new glucose, and glucose-free osmotic agents.
Use of one bag of glucose peritoneal dialysis fluid (PDF) results in the development of a dose-related senescent mesothelial cell phenotype not linked to acidic pH or the presence of lactate buffer. This complication derives mostly from oxidative stress induced both by glucose itself and by glucose degradation products (GDPs). New glucose formulations are offered in dual- or three-chambered bag...
متن کاملCytotoxic Glucose Degradation Products in Fluids for Peritoneal Dialysis
During the standard heat sterilization process of the lactate–buffered peritoneal dialysis solutions, glucose (an osmotic active substance) degrades to form compounds called glucose degradation products which are cytotoxic and affect the survival of the peritoneal membrane. This case presentation is based on an observation of 224 aseptic peritonitis cases of unknown etiology. For the purpose of...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical journal of the American Society of Nephrology : CJASN
دوره 8 1 شماره
صفحات -
تاریخ انتشار 2013