Electrospray mass spectrometry for measurement of glycohemoglobin.

نویسنده

  • K Miedema
چکیده

With the publication of the results of the landmark 9-year Diabetes Control and Complications Trial (DCCT), the importance of Hb A1c/glycohemoglobin testing in diabetes was firmly established. The DCCT showed, at least in patients with insulin-dependent diabetes mellitus, that the risk for development and progression of the chronic complications of diabetes is closely related to the degree of metabolic control as measured by glycohemoglobin determinations [1]. Generally, the same is believed to be true for patients with non-insulin-dependent diabetes mellitus, although the results of the UK Prospective Study must be awaited [2, 3]. The DCCT has confirmed that measuring glycohemoglobin in blood is an excellent tool for the long-term control of the glycemic state. Considering the high prevalence of diabetes mellitus, glycohemoglobin is one of the most important analytes in laboratory medicine today [4]. A major task of clinical chemistry should be to optimize conditions for its determination. The development of new methodologies and international standardization is an essential part of such efforts. Despite the ongoing efforts for standardization of Hb A1c/glycohemoglobin [5], many glycohemoglobin assays are not standardized among clinical laboratories; values reported by one laboratory may not agree with those from another, and possibly neither would agree with those from the DCCT [6]. Glycohemoglobins are the products of a nonenzymatic reaction between the free aldehyde group of glucose (Hb A1c) or other sugars and the unprotonated form of free amino groups of hemoglobin. The percentage of glycohemoglobin in human blood depends on the concentration of glucose, the duration of glucose exposure to hemoglobin, and the turnover of erythrocytes. The higher the glucose concentration and the longer the exposure time, the higher the percentage of Hb A1c. The potential glycation sites of the hemoglobin A molecule are the N-terminal amino acid valine of the four polypeptide chains (a2b2) and all free e-amino groups of lysine within these chains. The predominant glycation site is the N-terminal valine residue of the b-chain, which accounts for ;60% of all bound glucose. This glycation product is generally referred to as Hb A1c. The remaining glucose is bound to one of the 44 glycation sites at the e-amino groups within the aand b-chains or at the N-terminal valine of the a-chain [7, 8]. Many analytical methods for measuring glycohemoglobin in human blood are currently being used by clinical laboratories, methods based on physical, chemical, or immunological differences between glycated (Hb A1c) and nonglycated hemoglobin (Hb A0). Ion-exchange chromatography (HPLC systems, minicolumns), electrophoresis, and isoelectric focusing methods exploit the charge differences between Hb A0 and Hb A1c (the attachment of glucose to the N-terminal amino group of the b-chain changes the isoelectric point of hemoglobin). However, the homogeneity of the Hb A1c peak is seriously questionable and many possible interferences are known, so the specificity of this kind of technique remains uncertain. Affinity-chromatographic methods (minicolumns, automated systems, HPLC systems) are based on the reaction of the cis-1,2-diol groups of hemoglobin-bound glucose (and other sugars) with immobilized boronic acid, forming a boronate ester. In theory, all sugar adducts of hemoglobin in human blood can be bound; hence, the amount of total glycohemoglobin is measured. Unlike cation-exchange HPLC, affinity chromatography is less susceptible to interfering substances (e.g., carbamylated hemoglobin, acetylated hemoglobin, hemoglobin variants, or degradation products). In the last few years, the spectrum of methods has been broadened by the addition of immunological methods (enzyme immunoassays, latex agglutination inhibition assays, homogeneous immunoassays), which are being used by an increasing number of laboratories. These methods use monoclonal or polyclonal antibodies directed against the glycated N-terminal group of the b-chain of hemoglobin (last 4, 6, or 8 amino acids) and are therefore specific for the type of glycation seen in Hb A1c (although glycation of many genetic variant hemoglobins produces the same N-terminal structure). As a result of these recent developments, medical laboratories can currently choose from .20 different commercially available tests for measuring Hb A1c, Hb A1, or total glycohemoglobin in human blood. In addition, there is a trend towards an increasing use of automated laboratory systems. Unfortunately, the global application of current methods is limited by a lack of appropriate standardization. Early efforts to standardize Hb A1c/glycohemoglobin values among clinical laboratories by using a “universal calibrator” proved feasible with some methods, but did not work for several others [5, 9]. In particular, because the chemical entity to be analyzed was not defined, a reference system could not be set up. Therefore, both the AACC Subcommittee on Glycohemoglobin Standardization and the IFCC Working Group on Standardization of HbA1c proposed that the method used in the DCCT study be regarded as the “designated comparison method,” against which most if not all assay methods should be standardized, while waiting for development of a scientifically sound reference system [10]. Several studies have demonstrated that the amount of glycohemoglobin measured by cation-exchange chromatography, affinity chromatography, and immunoturbidimetric assays equally well reflects the degree of glycemic control in diabetics. Correlation studies between cationexchange vs boronate-affinity chromatography have shown that, in the lower range of percentage glycation values, the affinity methods measure lower glycohemoglobin values because the heterogeneity of the Hb A1c Editorial

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Glycohemoglobin: a primary predictor of the development or reversal of complications of diabetes mellitus.

BACKGROUND Diabetes mellitus is a major health problem worldwide with long-term micro- and macrovascular complications responsible for a majority of its morbidity and mortality. The development and progression of these complications relate strongly to glycemic control. METHODS We reviewed the literature extensively for studies that relate glycemic control to the development and progression of...

متن کامل

Potential of electrospray mass spectrometry for quantifying glycohemoglobin.

An electrospray ionization-mass spectrometric procedure has been developed for determining glycohemoglobin. Whole-blood samples from 78 diabetic and 50 nondiabetic subjects (glycation range 3-15%, as determined by electrospray mass spectrometry) were diluted 500-fold in an acidic denaturing solvent and introduced directly into a mass spectrometer. The resulting mass spectra were then processed ...

متن کامل

Long-term evaluation of electrospray ionization mass spectrometric analysis of glycated hemoglobin.

BACKGROUND Electrospray ionization mass spectrometry (ESIMS) has been successfully applied to the identification of hemoglobin (Hb) variants and the presence of glucose adducts (mass difference of 162 Da) on the separate Hb alpha and beta chains. To establish the potential of ESIMS as a routine and/or a reference method for the quantification of glycohemoglobin (HbA1c), we carried out a detaile...

متن کامل

A Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study

     A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...

متن کامل

A Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study

     A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...

متن کامل

What is hemoglobin A1c? An analysis of glycated hemoglobins by electrospray ionization mass spectrometry.

Hemoglobin A1c (HbA1c) is a stable minor Hb variant formed in vivo by posttranslational modification by glucose, originally identified by using cation exchange chromatography, and containing primarily glycated N-terminal beta-chains. However, the structure(s) of the quantified species has not been elucidated, and the available methods lack a reference standard. We used electrospray ionization m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 43 5  شماره 

صفحات  -

تاریخ انتشار 1997