The value of “constant sharpness” as a diagnostic sign in MR-Mammography

نویسندگان

  • Clemens G. Kaiser
  • Pascal Baltzer
  • Anna K. Kaiser
  • Julia Krammer
  • Michael Uder
  • Werner A. Kaiser
  • Matthias Dietzel
چکیده

PURPOSE To examine "constant lesion sharpness" as a morphological diagnostic sign in the differential diagnosis between benign and malignant lesions. MATERIAL AND METHODS This prospective study had institutional review board approval and was HIPAA compliant. In total 1014 consecutive patients were examined (mean age 55 years ± 13 years) and evaluated in our University hospital towards the morphological shape of the lesion borders. The "Constant sharpness Sign" was defined as a lesion remaining continuously sharp for the duration of the dynamic scan. Inclusion criteria were unclear findings (e.g. BIRADS III/IV), Preoperative staging (BRIDAS IV/V), and referred patients from local clinic of gynecology. Exclusion criteria were MRM-examination ≤1 year before, status after surgery and/or biopsy, chemotherapy and/or radiation therapy. Reference Standard was histological verification. Images were diagnosed by two experienced radiologists in consensus, blinded to the standard of reference. RESULTS 1014 patients with 1084 lesions (436 benign, 648 malignant lesions) were included into the study. 41.5% of benign lesions and 6.8% (181/436) of malignant lesions displayed a constant sharpness as an accompanying morphological sign (P < 0.001). This resulted in a sensitivity of 41.5%, specificity of 93.2%, a positive likelihood ratio of 6.1%, a negative likelihood ratio of 0.63 and an odd's ratio of 9,7%. SUMMARY AND CONCLUSION The constant sharpness sign seems to be an accurate predictor of benign breast lesions, which may help to increase the accuracy of MRM as a morphological sign.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Comparison of the effectiveness of Mammographic Film-Screen and Standard Film-Screen in the Detection of Small Bone Fractures

The use of mammography film-screen is limited in general radiography. The purpose of this study was to compare the effectiveness of mammographic film-screen and standard film-screen systems in the detection of small bone fractures. Radiographs were taken from patients' extremities and neck areas using mammography film-screen and standard film-screen (n=57 each). Fourteen other radiographs were ...

متن کامل

Diagnostic Value of Ischial Spine Sign in Patients with Acetabular Retroversion

Background: Acetabular Retroversion (AR) is a hip disorder and one of the causes of pain in this area. Evaluationof positive Cross Over Sign (COS) on AP X-Rays of the hip is currently the best method of diagnosis of AR. Severalstudies have measured co-existence of Ischial Spine Sign (ISS) in patients with AR. In this study we evaluated thediagnostic value of ISS in confirmation of AR and compar...

متن کامل

Clinical assessment of complex valued combinations of ip- and op-data in MR mammography

Introduction It has been shown that the combined use of complex valued in-phase (ip) and opposed-phase (op) images can improve the signal to noise ratio (SNR) of dynamic MR mammography (MRM)[1] compared to conventional ip-subtraction (SIPCN). While improved SNR is certainly helpful, this study is comparing the overall image quality and especially the lesion sharpness of four different contrasts...

متن کامل

Assessment of Computer Regulation Thermography (CRT) as a Complemetrary Diagnostic tool for Breast Cancer Patient

Background: Breast cancer is the most common type of cancer in women demanding accurate diagnosis to take remedial measures to treat.Objective: Comparing the diagnostic capability of the computer regulation thermography (CRT), as a novel and safe diagnostic procedure, with common methods including sonography, mammography and clinical examinations for diagnosing breast cancer in suspicious...

متن کامل

A Comparative Study of the Diagnostic Value of Contrast-Enhanced Breast MR Imaging and Mammography on Patients with BI-RADS 3–5 Microcalcifications

OBJECTIVE To retrospectively investigate the diagnostic value of breast MRI in patients with BI-RADS 3-5 microcalcifications in mammography. METHODS Eighty-four patients with BI-RADS 3-5 microcalcifications on mammography underwent breast MR exams before surgical biopsy with a hookwire position under mammographic guidance. Two radiologists reviewed each lesion with BI-RADS by consensus. The d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2016