Comparative dosimetric findings using accelerated partial breast irradiation across five catheter subtypes
نویسندگان
چکیده
PURPOSE Accelerated partial breast irradiation (APBI) with balloon and strut adjusted volume implants (SAVI) show promising results with excellent tumor control and minimal toxicity. Knowing the factors that contribute to a high skin dose, rib dose, and D95 coverage may reduce toxicity, improve tumor control, and help properly predict patient outcomes following APBI. METHODS AND MATERIALS A retrospective analysis of 594 patients treated with brachytherapy based APBI at a single institution from May 2008 to September 2014 was grouped by applicator subtype. Patients were treated to a total of 34 Gy (3.4 Gy x 10 fractions over 5 days delivered BID) targeting a planning target volume (PTV) 1.0 cm beyond the lumpectomy cavity using a high dose rate source. RESULTS SAVI devices had the lowest statistically significant values of DmaxSkin (81.00 ± 29.83), highest values of D90 (101.50 ± 3.66), and D95 (96.09 ± 4.55). SAVI-mini devices had the lowest statistically significant values of DmaxRib (77.66 ± 32.92) and smallest V150 (18.01 ± 3.39). Multi-lumen balloons were able to obtain the smallest V200 (5.89 ± 2.21). Strut-based applicators were more likely to achieve a DmaxSkin and a DmaxRib less than or equal to 100 %. The effect of PTV on V150 showed a strong positive relationship (p < .001). PTV and DmaxSkin showed a weak negative relationship in multi-lumen applicators (p = .016) and SAVI-mini devices (p < .001). PTV and DmaxRib showed a weak negative relationship in multi-lumen applicators (p = .009), SAVI devices (p < .001), and SAVI-mini devices (p < .001). CONCLUSION PTV volume is strongly correlated with V150 in all devices and V200 in strut based devices. Larger PTV volumes result in greater V150 and V200, which could help predict potential risks for hotspots and resulting toxicities in these devices. PTV volume is also weakly negatively correlated with max skin dose and max rib dose, meaning that as the PTV volumes increase one can expect slightly smaller max skin and rib doses. Strut based applicators are significantly more effective in keeping skin and rib dose constraints under 125 and 100 % when compared to any balloon based applicator.
منابع مشابه
Dosimetric Improvements in Balloon Based Brachytherapy Using the Contura® Multi-Lumen Balloon (MLB) Catheter to Deliver Accelerated Partial Breast Irradiation
PURPOSE Preliminary dosimetric findings in patients managed with the Contura® Multi-Lumen Balloon (MLB) breast brachytherapy catheter to deliver accelerated partial breast irradiation (APBI) on a multi-institutional phase IV registry trial were reviewed. MATERIAL AND METHODS CT-based 3D planning with dose optimization was performed for all patients. For the study, new ideal dosimetric goals w...
متن کاملProjected Improvements in Accelerated Partial Breast Irradiation Using a Novel Breast Stereotactic Radiotherapy Device: A Dosimetric Analysis
Accelerated partial breast irradiation has caused higher than expected rates of poor cosmesis. At our institution, a novel breast stereotactic radiotherapy device has demonstrated dosimetric distributions similar to those in brachytherapy. This study analyzed comparative dose distributions achieved with the device and intensity-modulated radiation therapy accelerated partial breast irradiation....
متن کاملMulti-catheter interstitial accelerated partial breast irradiation – tips and tricks for a good insertion
Adjuvant radiotherapy is recommended post breast conserving surgery. Accelerated Partial Breast Irradiation (APBI) offers a more attractive shorter course of treatment over 5 days compared to standard conventional external beam radiotherapy, which is often protracted. Multi-catheter interstitial APBI offers excellent dosimetric coverage. This article describes two insertion techniques for multi...
متن کاملDosimetric considerations and early clinical experience of accelerated partial breast irradiation using multi-lumen applicators in the setting of breast augmentation
PURPOSE Accelerated partial breast irradiation (APBI) is an accepted treatment option in breast-conserving therapy for early stage breast cancer. However, data regarding outcomes of patients treated with multi-lumen catheter systems who have existing breast implants is limited. The purpose of this study was to report treatment parameters, outcomes, and possible dosimetric correlation with cosme...
متن کاملPersistent seroma after intraoperative placement of MammoSite for accelerated partial breast irradiation: incidence, pathologic anatomy, and contributing factors.
PURPOSE To investigate the incidence of, and possible factors associated with, seroma formation after intraoperative placement of the MammoSite catheter for accelerated partial breast irradiation. METHODS AND MATERIALS This study evaluated 38 patients who had undergone intraoperative MammoSite catheter placement at lumpectomy or reexcision followed by accelerated partial breast irradiation wi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 10 شماره
صفحات -
تاریخ انتشار 2015