Implant-supported overdenture with prefabricated bar attachment system in mandibular edentulous patient
نویسندگان
چکیده
Implant-supported overdenture is a reliable treatment option for the patients with edentulous mandible when they have difficulty in using complete dentures. Several options have been used for implant-supported overdenture attachments. Among these, bar attachment system has greater retention and better maintainability than others. SFI-Bar® is prefabricated and can be adjustable at chairside. Therefore, laboratory procedures such as soldering and welding are unnecessary, which leads to fewer errors and lower costs. A 67-year-old female patient presented, complaining of mobility of lower anterior teeth with old denture. She had been wearing complete denture in the maxilla and removable partial denture in the mandible with severe bone loss. After extracting the teeth, two implants were placed in front of mental foramen, and SFI-Bar® was connected. A tube bar was seated to two adapters through large ball joints and fixation screws, connecting each implant. The length of the tube bar was adjusted according to inter-implant distance. Then, a female part was attached to the bar beneath the new denture. This clinical report describes two-implant-supported overdenture using the SFI-Bar® system in a mandibular edentulous patient.
منابع مشابه
Comparison of the Effect of Ball and Bar Attachment Designs on Retention and Stability of Mandibular Implant-Supported Overdentures
Objectives: The present study evaluated the effect of bar and ball attachment designs on retention and stability of a mandibular overdenture supported by four implants. Methods: An edentulous mandibular acrylic resin model with four implants in the anterior part of the ridge (A, B, D and E) was fabricated. A metal framework simulating the overdenture was also fabricated. Totally, 30...
متن کاملComparison of prefabricated and custom-made bars used for implant-retained mandibular complete overdentures.
PURPOSE To compare prefabricated and custom-made bars used for implant-retained mandibular complete overdentures. MATERIALS Ten completely edentulous patients were selected for replacement with dental implants. Each patient received 2 (press-fit) dental implants, 1 implant on each side in the canine regions of the mandible. The implants were left submerged (unloaded) for a healing osseointegr...
متن کاملFabricating CAD/CAM Implant-Retained Mandibular Bar Overdentures: A Clinical and Technical Overview
This report describes the clinical and technical aspects in the oral rehabilitation of an edentulous patient with knife-edge ridge at the mandibular anterior edentulous region, using implant-retained overdentures. The application of computer-aided design and computer-aided manufacturing (CAD/CAM) in the fabrication of the overdenture framework simplifies the laboratory process of the implant pr...
متن کاملComparison of stresses transferred to the implant supported overdentures with bar, ball and zaag attachments through photoelasticity
Comparison of stresses transferred to the implant supported overdentures with bar, ball and zaag attachments through photoelasticity Dr. A. Saboori* - Dr. Gh. Esfahanizade** - Dr. M. Ejlali*** *- Assistant Professor of Prosthodontics Dept. - Faculty of Dentistry – Shaheed Beheshti University of Medical Sciences. **- Assistant Professor of Prosthodontics Dept. - Faculty of Dentistry – Tehran Isl...
متن کاملAn in vitro comparative study to evaluate the retention of different attachment systems used in implant-retained overdentures
AIM The aim of this in vitro study was to compare the change in the retentive force and removal torque of three attachment systems during simulation of insertion-removal cycles. METHODOLOGY Edentulous mandibular models were made with heat-cured polymethyl methacrylate resin. Two implant replicas (CMI), of 3.75 mm diameter and 10 mm length, were placed in the intraforaminal region. Acrylic res...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 4 شماره
صفحات -
تاریخ انتشار 2012