Enzyme immunoassay and enzyme inhibition assay of methotrexate, with use of the centrifugal analyzer.

نویسندگان

  • M A Pesce
  • S H Bodourian
چکیده

Methotrexate was determined by the homogeneous enzyme immunoassay (EMIT) with the Multistat and CentrifiChem centrifugal analyzers and by the enzyme inhibition assay with use of the Multistat centrifugal analyzer. With both methods, the standard curve extends from 0.2 to 2.0 mumol/L and there is no interference from bilirubin in concentrations up to 100 mg/L. Moderately lipemic samples do not interfere with the EMIT method, but lower the values obtained with the enzyme inhibition assay. Hemoglobin concentrations as great as 1 g/L do not affect results for methotrexate obtained by the enzyme inhibition assay. With the EMIT assay, methotrexate values are lowered in samples containing hemoglobin in concentrations exceeding 750 mg/L. With the EMIT assay, the following compounds in concentrations of 1 mmol/L do not interfere: leucovorin, 5-methyl-tetrahydrofolate, 5-fluorouracil, and 6-mercaptopurine. When folic acid (100 mumol/L) was added to a serum that did not contain methotrexate, a response equivalent to 0.15 mumol/L was obtained. Methotrexate is stable for five days in serum stored at 23, 4, or -20 degrees C. Within-run precision (CV) for the enzyme inhibition method ranged from 4.7 to 8.1% and for the EMIT assay from 2.5 to 6.2%. Methotrexate concentrations in the serum of children receiving high-dose therapy were compared by three methods: competitive protein binding, EMIT, and enzyme inhibition assays. The correlation coefficients averaged 0.95.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Adaptation of the enzyme-multiplied immunoassay for methotrexate to the centrifugal analyzer.

We adapted the homogeneous enzyme-multiplied immunoassay for methotrexate to the centrifugal analyzer. The sensitivity of the assay has been extended from 200 nmol/L down to 12.5 nmol/L. Several protocols may be followed, depending on whether the samples to be tested are from patients on low- or high-dose methotrexate regimens. Precision, accuracy, and sensitivity were satisfactory. Comparison ...

متن کامل

Homogeneous enzyme immunoassay for theophylline with a centrifugal analyzer.

A rapid homogeneous enzyme immunoassay for theophylline has been adapted to a centrifugal analyzer. The sample volume used was 10 microliter and sera from as many as 28 patients could be measured in 180 seconds. The assay temperature was 30 degrees and the absorbance rates were measured at 340 nm. Within-run and run-to-run precision showed a coefficient of variation of less than 2.6 and 7.5 per...

متن کامل

Centrifugal analyzer used for enzyme immunoassay of progesterone and choriomammotropin.

Recently we developed an enzyme immunoassay involving the use of steroid delta-isomerase (EC 5.3.3.1) as enzyme label and exclusion-affinity chromatography for rapid separation of free antigen-enzyme conjugate that bound to antibodies (J. Immunol. Methods 35: 267-284, 1980). Here we describe an automated version of this procedure, for immunoassay of progesterone and choriomammotropin (human pla...

متن کامل

Quantitation of haptens by homogeneous immunoprecipitation. 2. Centrifugal analysis for tobramycin, phenobarbital, and theophylline in serum.

Our homogeneous immunoprecipitation inhibition assay (Clin. Chem. 28:659-661, 1982) is applied here to tobramycin, phenobarbital, and theophylline. Only 10-50 microL of test sample is needed. No sample treatment, dilution, or extraction is required. A test serum sample is simultaneously mixed with a drug conjugate and its specific antiserum in a centrifugal analyzer. The subsequent reaction and...

متن کامل

Determination of methotrexate in serum by a rapid, fully mechanized enzyme immunoassay (EMIT).

A homogeneous enzyme immunoassay for the determination of methotrexate in serum (EMIT, Syva Corp.) was fully mechanized by the use of an Eppendorf analyzer 5010. Coefficients of variation from day to day were in the range 2--16%. A comparison of the results obtained by EMIT and a radioimmunoassay (Methotrexate 125 I Radioimmunoassay Kit, Diagnostic Biochemistry Inc.) in a series of 50 samples f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 27 3  شماره 

صفحات  -

تاریخ انتشار 1981