High-performance liquid chromatography of selected organic peroxides with oxidative amperometric detection.

نویسنده

  • O Evans
چکیده

Reversed-phase high-performance liquid chromatography with oxidative amperometric detection was optimized for the determination of several organic peroxides in drinking water under ideal conditions. The determinations were performed under isocratic conditions using acetonitrile and methanol as the organic modifiers with 0.05 M potassium phosphate buffer solution. The oxidative amperometric response of the organic peroxides was dependent on the concentration of organic modifier and the electrode potential. The optimum electrode potential (EOxAPP), for the simultaneous determination of the organic peroxides was approximately +1.150 +/- 0.05 V versus the Ag/AgCl reference electrode. The maximum analytical signal for butan-2-one peroxide and tert-butyl hydroperoxide, when using acetonitrile, was obtained with 20% v/v organic modifier. For cumene hydroperoxide, the maximum analytical signal was achieved with approximately 35% v/v acetonitrile. The retention time of cumene hydroperoxide, on an octyldecylsilane column (250 x 4 mm id), decreased sharply from > 100 to < 10 min when the organic modifier concentration was varied from 5 to 50% v/v. The retention time of butan-2-one and tert-butyl hydroperoxide, under the same conditions, varied by < 10 min. The calibration curves for the aliphatic peroxides and aromatic peroxide were linear from 2 to 200 ng and from 0.2 to 200 ng injected, respectively.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

On-line deoxygenation in reductive (and oxidative) amperometric detection: environmental applications in the liquid chromatography of organic peroxides

Cyclic voltammetry was used qualitatively to characterize and determine the feasibility of the oxidation and reduction of selected organic peroxides and hydroperoxides at a glassy carbon electrode. Organic peroxides were determined using reversed-phase high-performance liquid chromatography with simultaneous reductive and oxidative amperometric detection in a thin-layer dual parallel–adjacent e...

متن کامل

Uncovering Deficiencies in Mass Balance Using HPLC with Chemiluminescence Nitrogen-Specific Detection

with amperometric detection. It has been shown elsewhere that the selectivity of this method is sufficient to separate the potential organic impurities; that is, synthesis byproducts and a specified degradation product from the drug substance (3). The objective of this article is to demonstrate that this method’s suitability for stability testing can be evaluated easily by performing HPLC with ...

متن کامل

Simulataneous Analysis of Trimethoprim and Sulphamethoxazole Drug Combinations in Dosage Forms by High Performance Liquid Chromatography

A sensitive high performance liquid chromathography (HPLC) analytical procedure was developed for the quantitive determination of trimethoprim (TM* and sulphamethoxazole (SM) in commercial dosage forms. C18 analytical column (stainless steel, 25 cm * 4.6 mm i.d.) was packed with 5-*m particles of the reversed phase material and used for assays. Mobile phase containing 0.025 M sodium phosphate...

متن کامل

High Performance Liquid Chromatography Coupled with Pre-column Derivatization for Determination of Oxidized Glutathione Level in Rats Exposed to Paraquat

Glutathione (GSH) is one of the most important antioxidants that plays an essential role in detoxification of reactive oxygen species (ROS) which oxidizes to glutathione disulfide (GSSG). Paraquat (PQ), awidely used herbicide, causes pulmonary injury with the productionof ROS. Excessive ROS accumulation as a consequence of PQ exposure are frequently targeted by GSH thereby oxidative stress lead...

متن کامل

High Performance Liquid Chromatography Coupled with Pre-column Derivatization for Determination of Oxidized Glutathione Level in Rats Exposed to Paraquat

Glutathione (GSH) is one of the most important antioxidants that plays an essential role in detoxification of reactive oxygen species (ROS) which oxidizes to glutathione disulfide (GSSG). Paraquat (PQ), awidely used herbicide, causes pulmonary injury with the productionof ROS. Excessive ROS accumulation as a consequence of PQ exposure are frequently targeted by GSH thereby oxidative stress lead...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Analyst

دوره 123 4  شماره 

صفحات  -

تاریخ انتشار 1998