Determining indoor air quality and identifying the origin of odour episodes in indoor environments.

نویسندگان

  • Eva Gallego
  • Xavier Roca
  • Jose Francisco Perales
  • Xavier Guardino
چکیده

A methodology for identifying volatile organic compounds (VOCs) and determining air quality of indoor air has been developed. The air samples are collected using pump samplers by the inhabitants when they perceive odorous and/or discomfort episodes. Glass multi-sorbent tubes are connected to the pump samplers for the retention of VOC. The analysis is performed by automatic thermal desorption (ATD) coupled with gas chromatography-mass spectrometry (GC/MS). This methodology can be applied in cases of sick building syndrome (SBS) evaluation, in which building occupants experience a series of varied symptoms that appear to be linked to time spent in the building. Chemical pollutants concentrations (e.g., VOC) have been described to contribute to SBS. To exemplify the methodology, a qualitative determination and an evaluation of existing VOC were performed in a dwelling where the occupants experienced the SBS symptoms. Higher total VOC (TVOC) levels were detected during episodes in indoor air (1.33 +/- 1.53 mg/m3) compared to outdoor air (0.71 +/- 0.46 mg/m3). The concentrations of individual VOCs, such as ethanol, acetone, isopropanol, 1-butanol, acetic acid, acetonitrile and 1-methoxy-2-propanol, were also higher than the expected for a standard dwelling. The external source of VOC was found to be an undeclared activity of storage and manipulation of solvents located at the bottom of a contiguous building.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Indoor air quality monitoring in urban areas using Smart Sensing Technology

Recently, indoor air quality has attracted the attention of policymakers and researchers as a critical issue like that of external air pollution. Indoor air quality is more important as people spend time longer indoors than outdoors. Indoor environments are closed compared to external environments providing less opportunity for the pollutants to dilute. The emissions contain many substances tha...

متن کامل

Assessment of the Indoor Odour Impact in a Naturally Ventilated Room

Indoor air quality influences people's lives, potentially affecting their health and comfort. Nowadays, ventilation is the only technique commonly used for regulating indoor air quality. CO₂ is the reference species considered in order to calculate the air exchange rates of indoor environments. Indeed, regarding air quality, the presence of pleasant or unpleasant odours can strongly influence t...

متن کامل

بررسی غلظت مونواکسیدکربن هوای داخل ساختمان و هوای آزاد شهر بیرجند (شهریور تا اسفند 1393)

Background and Aim: One of the notorious  air pllutants on which air quality is determined is  carbon monoxide (CO). The aim of the present study was to measure the concentration of CO outdoor and indoor urban environments and compare it with air quality standards within buildings  and open spaces. Materials and Methods: This research was a descriptive-analytical study of CO estimation in ou...

متن کامل

An Assessment of Indoor Air Quality and Thermal Comfort in Educational Spaces (Case Study: Girls' High Schools in Arak, Iran)

As s‌tudents spend one-third of their time at school, their health, comfort, and productivity are mos‌tly influenced by thermal condition and indoor air quality of classrooms. Regarding that manual window-opening is a common way for providing fresh air in classes and s‌tudents aren't allowed to change their uniform, position or control the windows during the lesson hours, providing thermal comf...

متن کامل

Indoor and Outdoor Air Fungus Bioaerosols in Khorramabad Day Care Child Centers Western of Iran, 2018

Introduction: the aim of this study was to determine the quantity and quality of indoor and outdoor air fungus bioaerosols in Khorramabad day care child centers. Materials and Methods: A total of 180 air samples were collected from 10 centers in 2018. The samples included 7 indoor and 2 outdoor sampling points. The total number of children was 580. Sampling of fungal bioaerosols was performed ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of environmental sciences

دوره 21 3  شماره 

صفحات  -

تاریخ انتشار 2009