Time course of ECG depolarization and repolarization changes during ischemia in PTCA recordings.

نویسندگان

  • E Pueyo
  • J García
  • G Wagner
  • R Bailón
  • L Sörnmo
  • P Laguna
چکیده

OBJECTIVES In this work we studied the temporal evolution of changes in the electrocardiogram (ECG) as a consequence of the induced ischemia during prolonged coronary angioplasty, comparing the time course of indexes reflecting depolarization and those reflecting repolarization. METHODS We considered both local (measured at specific points of the ECG) and global (obtained from the Karhunen-Loève transform) indexes. In particular, the evolution of Q, R and S wave amplitudes during ischemia was analyzed with respect to classical indexes such as ST level. As a measurement of sensitivity we used an Ischemic Changes Sensor (ICS), which reflects the capacity of an index to detect changes in the ECG. RESULTS The results showed that, in leads with low-amplitude ST-T complexes, the S wave amplitude was more sensitive in detecting ischemia than was the commonly used index ST60. It was found that in such leads the S wave amplitude initially exhibited a delayed response to ischemia when compared to ST60, but its performance was better from the second minute of occlusion. The global indexes describing the ST-T complex were, in terms of the ICS, superior to the S wave amplitude for ischemia detection. CONCLUSIONS Ischemic ECG changes occur both at repolarization and depolarization, with alterations in the depolarization period appearing later in time. Local indexes are less sensitive to ischemia than global ones.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Characterization of ventricular depolarization and repolarization changes in a porcine model of myocardial infarction.

In this study, several electrocardiogram (ECG)-derived indices corresponding to both ventricular depolarization and repolarization were evaluated during acute myocardial ischemia in an experimental model of myocardial infarction produced by 40 min coronary balloon inflation in 13 pigs. Significant changes were rapidly observed from minute 4 after the start of coronary occlusion, achieving their...

متن کامل

Imaging electrocardiographic dispersion of depolarization and repolarization during ischemia: simultaneous body surface and epicardial mapping.

BACKGROUND Myocardial ischemia creates abnormal electrophysiological substrates that result in life-threatening ventricular arrhythmias. Identifying patients at risk of such abnormalities by use of body surface electrical measures is controversial. We investigated the sensitivity of torso measures, recorded simultaneously with epicardial electrograms, to changes in dispersion of depolarization ...

متن کامل

رابطه بین تغییرات آینه ای (Reciprocal changes) الکتروکاردیوگرام بیماران دچار انفارکتوس حاد میوکارد و تنگی عروق کرونر تغذیه کننده نواحی مربوط به تغییرات

Introduction: Reciprocal changes are ST depression ≥1 mm in electrocardiogram of the patients with acute myocardial infarction in the reciprocal leads. This question that these changes are merely secondary to ST elevation in infarction area or that they are truly subendocardial ischemia secondary to involvement of coronary artery that perfuse that area is not clearly defined. Methods and Materi...

متن کامل

Value of the intracoronary electrocardiogram to monitor myocardial ischemia during percutaneous transluminal coronary angioplasty.

To enhance detection of ischemia during percutaneous transluminal coronary angioplasty (PTCA), unipolar intracoronary electrocardiograms (ECGs) were recorded during PTCA in 25 patients from the tips of guidewires positioned distal to stenoses being dilated. Surface electrocardiographic leads chosen to reflect likely areas of reversible ischemia during PTCA were recorded simultaneously. In 21 of...

متن کامل

Detection of transient myocardial ischemia by computer analysis of standard and signal-averaged high-frequency electrocardiograms in patients undergoing percutaneous transluminal coronary angioplasty.

Electrocardiographic manifestations of transient myocardial ischemia were studied, in 11 patients undergoing angioplasty (PTCA) of a left anterior descending coronary artery stenosis, by the visual inspection of the standard surface electrocardiogram (S-ECG) and the intracoronary ECG (IC-ECG) as well as computer-assisted analysis of the S-ECG. Cross-correlation analysis (CCA) performed by compu...

متن کامل