Surface electromyographic mapping of the orbicularis oculi muscle for real-time blink detection.
نویسندگان
چکیده
IMPORTANCE Facial paralysis is a life-altering condition that significantly impairs function, appearance, and communication. Facial rehabilitation via closed-loop pacing represents a potential but as yet theoretical approach to reanimation. A first critical step toward closed-loop facial pacing in cases of unilateral paralysis is the detection of healthy movements to use as a trigger to prosthetically elicit automatic artificial movements on the contralateral side of the face. OBJECTIVES To test and to maximize the performance of an electromyography (EMG)-based blink detection system for applications in closed-loop facial pacing. DESIGN, SETTING, AND PARTICIPANTS Blinking was detected across the periocular region by means of multichannel surface EMG at an academic neuroengineering and medical robotics laboratory among 15 healthy volunteers. MAIN OUTCOMES AND MEASURES Real-time blink detection was accomplished by mapping the surface of the orbicularis oculi muscle on one side of the face with a multichannel surface EMG. The biosignal from each channel was independently processed; custom software registered a blink when an amplitude-based or slope-based suprathreshold activity was detected. The experiments were performed when participants were relaxed and during the production of particular orofacial movements. An F1 score metric was used to analyze software performance in detecting blinks. RESULTS The maximal software performance was achieved when a blink was recorded from the superomedial orbit quadrant. At this recording location, the median F1 scores were 0.89 during spontaneous blinking, 0.82 when chewing gum, 0.80 when raising the eyebrows, and 0.70 when smiling. The overall performance of blink detection was significantly better at the superomedial quadrant (F1 score, 0.75) than at the traditionally used inferolateral quadrant (F1 score, 0.40) (P < .05). CONCLUSIONS AND RELEVANCE Electromyographic recording represents an accurate tool to detect spontaneous blinks as part of closed-loop facial pacing systems. The early detection of blink activity may allow real-time pacing via rapid triggering of contralateral muscles. Moreover, an EMG detection system can be integrated in external devices and in implanted neuroprostheses. A potential downside to this approach involves cross talk from adjacent muscles, which can be notably reduced by recording from the superomedial quadrant of the orbicularis oculi muscle and by applying proper signal processing. LEVEL OF EVIDENCE NA.
منابع مشابه
Observations on the blink reflex.
The blink reflex and its equivalent glabella tap reflex are behavioural motor responses normally found in neonates and in the physiological startle reflex. Historically, it was described by Overend in 1896 and soon afterwards by McCarthy and by Bekhterev who disputed its origins. Kugelberg in 1952 recorded the early-latency R1 and the late-latency R2 electromyographic responses from orbicularis...
متن کاملDynamic muscle transfer in facial nerve palsy: the use of contralateral orbicularis oculi muscle.
The aim of the study is to describe the results of dynamic muscle transfer with an orbicularis oculi muscle flap from the contralateral side to the paralyzed side in patients with House-Brackmann grade 6 facial nerve palsy. This case series included six patients who underwent dynamic muscle transfer with a flap of healthy orbicularis oculi muscle fibers from the contralateral side into the para...
متن کاملEyelid movements. Mechanisms and normal data.
This study provides a comprehensive description of upper eyelid movement in normal human subjects. Using the magnetic search coil technique to monitor lid position and modified skin electrodes to record orbicularis oculi electromyographic (EMG) activity, the authors found that the basic eyelid movements, blinks, and saccadic lid movements, can be uniquely and reliably characterized by their amp...
متن کاملA silent period in orbicularis oculi muscles of humans.
Surface electromyographic activity was recorded bilaterally from orbicularis oculi muscles when subjects relaxed and contracted eyelid muscles. Cutaneous reflex responses were evoked during both the relaxed and contraction states. Following reflex elicitation periods of muscle silence in orbicularis oculi were observed for about 10 to 15 ms after the ipsilateral R1 response and for up to 100 ms...
متن کاملThe human blink reflex.
A detailed study of the human blink reflex in the different parts of the orbicularis oculi muscle has been carried out. The first component of the blink reflex has been demonstrated in patients with Friedreich's ataxia, who have selective loss of large sensory fibres resulting in loss of proprioceptive input. It has been established that both components of the blink reflex are cutaneous reflexe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- JAMA facial plastic surgery
دوره 16 5 شماره
صفحات -
تاریخ انتشار 2014