Novel idea to monitor and measure blood hemoglobin noninvasively

نویسندگان

  • A. H. Ar-Rawi
  • W. Ibrahim
چکیده

Measuring blood hematocrit noninvasively is reviewed in this paper. Although there is an inclination to measure the hematocrit by determining the bioelectrical impedance of the blood, in vitro experimental methods still remain practically inapplicable. The blood sample size is determined when blood samples are examined. Determining the impedance and volume of blood is the biggest challenge in measuring the hematocrit noninvasively without drawing a blood sample. Calculating the blood impedance in vivo requires developing an impedance measurement using a multi-frequency method and also calculating the change in pressure simultaneously during the heart’s pulsatile cycle.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Survey of Serum Ferritin and Hemoglobin Levels of Mothers and their Newborns

ABSTRACT one of the best index to study the mother's Iron level is to measure the serum ferritin. The aim of this study is to find out the relationship between the serum ferritin in mothers and newborns, and therefore we use these indexes to assess the Iron depletion enemia in above subjects. In this study, hemoglobin, serum ferritin, transferrin saturation (%), serum iron, and total iron bi...

متن کامل

ارتباط گلبول‎های قرمز هسته‏دار خون بندناف نوزاد با الگوی غیرطبیعی ضربان قلب جنین

Background: The presence of increased numbers of nucleated red blood cell (NRBC) in the umbilical cord blood has been associated with states of relative hypoxia. Nucleated red blood cell counts are a potentially useful tool in estimating the degree and timing of intrauterine hypoxia. This may have important implication in determining causality in case of compromised infant. Cord blood NRBC coun...

متن کامل

Use of mitochondrial inhibitors to demonstrate that cytochrome oxidase near-infrared spectroscopy can measure mitochondrial dysfunction noninvasively in the brain.

The use of near-infrared spectroscopy to measure noninvasively changes in the redox state of cerebral cytochrome oxidase in vivo is controversial. We therefore tested these measurements using a multiwavelength detector in the neonatal pig brain. Exchange transfusion with perfluorocarbons revealed that the spectrum of cytochrome oxidase in the near-infrared was identical in the neonatal pig, the...

متن کامل

Evaluation of Electrical and Optical Plethysmography Sensors for Noninvasive Monitoring of Hemoglobin Concentration

Completely noninvasive monitoring of hemoglobin concentration has not yet been fully realized in the clinical setting. This study investigates the viability of measuring hemoglobin concentration noninvasively by evaluating the performance of two types of sensor using a tissue phantom perfused with a blood substitute. An electrical sensor designed to measure blood volume changes during the cardi...

متن کامل

The measurement of dyshemoglobins and total hemoglobin by pulse oximetry.

PURPOSE OF REVIEW Recent advances in pulse oximetry have made it possible to noninvasively measure total hemoglobin, as well as the two most common dyshemoglobins. This review will trace the development and clinical application of multiwavelength pulse oximetry. RECENT FINDINGS Until now, commercially produced pulse oximeters have utilized two wavelengths of light and could measure only the r...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010