In situ field measurement of leaf water potential using thermocouple psychrometers.

نویسندگان

  • M J Savage
  • H H Wiebe
  • A Cass
چکیده

Thermocouple psychrometers are the only instruments which can measure the in situ water potential of intact leaves, and which can possibly be used to monitor leaf water potential. Unfortunately, their usefulness is limited by a number of difficulties, among them fluctuating temperatures and temperature gradients within the psychrometer, sealing of the psychrometer chamber to the leaf, shading of the leaf by the psychrometer, and resistance to water vapor diffusion by the cuticle when the stomates are closed. Using Citrus jambhiri, we have tested several psychrometer design and operational modifications and showed that in situ psychrometric measurements compared favorably with simultaneous Scholander pressure chamber measurements on neighboring leaves when the latter were corrected for the osmotic potential.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Errors in measuring water potentials of small samples resulting from water adsorption by thermocouple psychrometer chambers.

The adsorption of water by thermocouple psychrometer assemblies is known to cause errors in the determination of water potential. Experiments were conducted to evaluate the effect of sample size and psychrometer chamber volume on measured water potentials of leaf discs, leaf segments, and sodium chloride solutions. Reasonable agreement was found between soybean (Glycine max L. Merr.) leaf water...

متن کامل

Comparison of water potentials measured by in situ psychrometry and pressure chamber in morphologically different species.

Leaf water potentials measured by in situ psychrometry were compared with leaf water potentials measured by the pressure chamber technique at various values of water potential in Helianthus annuus, Helianthus nuttallii, Vigna unguiculata, Nerium oleander, Pistacia vera, and Corylus avellana. In V. unguiculata, the leaf water potentials measured by the in situ psychrometer oscillated at the same...

متن کامل

Leaf water potential of differentially salinized plants.

Water and osmotic potential energies were measured with thermocouple psychrometers, at intervals during a 4-week period, in growing leaves of bean (Phaseolus vulgaris, var. Blue Lake) and barley (Hordeum vulgare, var. Liberty) plants having roots equally split between 2 differentially salinized nutrient solutions. The osmotic potentials of plants with half their roots in saline solutions were a...

متن کامل

Comparison of the dye method with the thermocouple psychrometer for measuring leaf water potentials.

The dye method for measuring water potential was examined and compared with the thermocouple psychrometer method in order to evaluate its usefulness for measuring leaf water potentials of forest trees and common laboratory plants. Psychrometer measurements are assumed to represent the true leaf water potentials. Because of the contamination of test solutions by cell sap and leaf surface residue...

متن کامل

Comparison of pressure chamber and thermocouple psychrometer determinations of leaf water status in tomato.

Although the pressure chamber has gained wide acceptance as a convenient method for the measurement of plant water status, the relationship between the pressure observed in the chamber and other parameters of plant water status remains unclear. If one assumes that the spatial arrangement of water in the shoot is the same under pressure as it was in the intact plant, the positive pressure (P) an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Plant physiology

دوره 73 3  شماره 

صفحات  -

تاریخ انتشار 1983