Clinical evaluation of the minitek differential system for identification of Enterobacteriaceae.

نویسندگان

  • P J Finklea
  • M S Cole
  • T M Sodeman
چکیده

Forty-one stock organisms and 581 fresh clinical isolates were used in comparing the Minitek system to conventional tubed media to determine if this system is feasible and accurate for a high-volume clinical microbiology laboratory. In addition to comparison with tubed media, the following parameters were tested: (i) reproducibility of disks, (ii) the effect of variation in inoculum size, (iii) the effect of the age of culture, and (iv) the effect of predispensing disks. A total of 5,947 disks were compared with tube reactions; 95.9% agreed on the initial reading. After repeating questionable tube and disk reactions, this agreement rose to 98.2%. Using the disk reactions and the identification schema currently in use with tubed media, 94.9% of the Minitek final identifications agreed with those of tubed media; 1.5% gave differing identifications and 3.6% were inconclusive. This system is accurate, inexpensive, flexible, and convenient.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the Minitek system for identification of Enterobacteriaceae.

Clinical isolates (869) and stock cultures (35) of Enterobacteriaceae were tested in parallel with the Minitek and conventional systems. The Minitek correctly identified 822 of 904 cultures. When a deoxyribonuclease plate was inoculated along with the Minitek, it was possible to speciate Enterobacteriaceae within 24 h. False-positive hydrogen sulfide reactions were the major fault with this sys...

متن کامل

Evaluation of the R/B and Minitek systems for identification of Enterobacteriaceae.

The R/B and Minitek systems for the identification of Enterobacteriaceae were evaluated, and the results were compared with those obtained by conventional methods. Both systems were rapid and allowed correct identification of about 85% of the 294 isolates (23 species) examined. The individual biochemical reactions showed an overall agreement of 92.6% and 93.1% for the R/B and Minitek systems, r...

متن کامل

Modified inoculum for the enteric Minitek system from positive blood cultures.

A modified Minitek inoculum procedure for the identification of Enterobacteriaceae from positive blood cultures was shown to be reliable. The method consisted of inoculating the Minitek enteric and nonfermenter broth with blood culture fluid and incubating the inoculum for 4 h before use.

متن کامل

Biochemical characteristics and identification of Enterobacteriaceae isolated from meats.

The isolation and identification of 2,220 Enterobacteriaceae from meats indicated that Escherichia coli biotype I, Enterobacter agglomerans, and Serratia liquefaciens were the principal types to be differentiated in meats. Citrobacter freundii, Klebsiella pneumoniae, Enterobacter cloacae, and Enterobacter hafniae were also commonly identified. Identification of isolates by the Encise II (Roche ...

متن کامل

Comparison of miniaturized multitest systems with conventional methodology for identification of Enterobacteriaceae from foods.

Four miniaturized multiple test systems were compared with tube methodology used to identify Enterobacteriaceae encountered in foods. Identification aids supplied with each system were used to assign names to isolates at the species level. For the 129 strains tested, the Minitek system demonstrated a 96.9 percent agreement with reactions in tubed media. The Inolex, Analytab, and PathoTec test s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 4 5  شماره 

صفحات  -

تاریخ انتشار 1976