Identification of Human Adenovirus in Respiratory Samples with Luminex Respiratory Virus Panel Fast V2 Assay and Real-Time Polymerase Chain Reaction.

نویسندگان

  • Susanna Esposito
  • Alessia Scala
  • Sonia Bianchini
  • Alberto Zampiero
  • Emilio Fossali
  • Nicola Principi
چکیده

In order to compare the last version of the Respiratory Virus Panel (RVP) Fast assay for human Adenovirus (hAdv) detection with a specific real-time polymerase chain reaction (qPCR), which is considered the gold standard for hAdv detection, nasopharyngeal samples collected from 309 children (age range, four months to eight years) with respiratory tract infection were tested using the RVP Fast v2 assay (Luminex Molecular Diagnostics, Inc., Toronto, ON, Canada) and a specific TaqMan qPCR to identify hAdv DNA. The RVP Fast v2 assay detected 30/61 (49.2%) hAdv infections that had been identified by real-time qPCR, demonstrating a significantly lower detection rate (p < 0.001). The sensitivity of the RVP Fast v2 assay in comparison to qPCR was lower in younger children (42.9% vs. 57.7%; Cohen's kappa coefficient, 0.53); in samples with co-infections (40.0% vs. 56.7%; Cohen's kappa coefficient, 0.52); and in samples with hAdv type C (45.9% vs. 57.1%; Cohen's kappa coefficient, 0.60). Samples with lower viral loads were associated with a significantly lower sensitivity of the RVP Fast v2 assay (35.1% vs. 68.2%, p = 0.01; Cohen's kappa coefficients, 0.49). The RVP Fast v2 assay has important limitations for the detection of hAdv and cannot be used to evaluate whether hAdvs are the main etiologic agent responsible for an outbreak or when epidemiological studies are performed.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of the Luminex xTAG Respiratory Viral Panel Fast v2 Assay With Anyplex II RV16 Detection Kit and AdvanSure RV Real-Time RT-PCR Assay for the Detection of Respiratory Viruses

BACKGROUND The accurate and rapid identification of the causative viruses is important for the timely diagnosis and management of respiratory infections. Multiplex molecular diagnostic techniques have been widely adopted to detect respiratory viruses. We compared the results of a newly upgraded, multiplex, molecular bead-based respiratory viral panel (RVP) assay with the results of Anyplex II R...

متن کامل

Development of Multiplex Reverse Transcription-Polymerase Chain Reaction for Simultaneous Detection of Influenza A, B and Adenoviruses

Background and objective:Millions of people in developing countries lose their lives due to acute respiratory infections, such as Influenza A & B and Adeno viruses. Given the importance of rapid identification of the virus, in this study the researchers attempted to design a method that enables detection of influenza A, B, and adenoviruses, quickly and simultaneously. ...

متن کامل

The Frequency Distribution of Parainfluenza, Adeno and Respiratory Syncytial Virus Infections in Children below 2 Years Old with Bronchiolititis, by Multiplex Polymerase Chain Reaction Method, Afzalipoor Hospital, Kerman, 2006

Background & Aims: Acute respiratory infections are common cause of mortality during childhood. This study was designed to determine the incidence of adenovirus, parainfluenza virus and respiratory syncytial virus in respiratory infections by Multiplex PCR method. Methods: This study included 168 children under 2 years of age with clinical diagnosis of bronchiolitis. Nasopharyngeal specimens we...

متن کامل

Comparison of the Luminex Respiratory Virus Panel fast assay with in-house real-time PCR for respiratory viral infection diagnosis.

The Luminex xTAG Respiratory Virus Panel (RVP) assay has been shown to offer improved diagnostic sensitivity over traditional viral culture methods and to have a sensitivity comparable to those of individual real-time nucleic acid tests for respiratory viruses. The objective of this retrospective study was to test a new, streamlined version of this assay, the RVP Fast assay, which requires cons...

متن کامل

Evaluation of the Luminex xTAG Respiratory Viral Panel FAST v2 assay for detection of multiple respiratory viral pathogens in

Background: Acute respiratory infections (ARI) are among the leading causes of hospitalization in children ≤5 years old. Rapid diagnostics of viral pathogens is essential to avoid unnecessary antibiotic treatment, thereby slowing down antibiotic-resistance. We evaluated the diagnostic performance of the Luminex xTAG Respiratory Viral Panel FAST v2 against viral specific PCR as reference assays ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • International journal of molecular sciences

دوره 17 3  شماره 

صفحات  -

تاریخ انتشار 2016