A Three-Dimensional Study of Body Motion During Ergometer Rowing

نویسندگان

  • Chiarella Sforza
  • Elena Casiraghi
  • Nicola Lovecchio
  • Domenico Galante
  • Virgilio F. Ferrario
چکیده

Background: Rowing movements can be simulated using specialized ergometers; the method can be used both for training and indoor assessment of body movements within controlled conditions. Purpose: To perform a three-dimensional quantitative analysis of body movements during ergometer rowing, and to examine if there is a relationship between anthropometry and rowing kinematics. Study Design: Descriptive Laboratory Study Methods: Body movements were recorded in 18 high-level oarsmen during ergometer rowing at 28 strokes/min. The three-dimensional movements of 21 body landmarks (left and right ankle, knee, greater trochanter, hip, shoulder, elbow, wrist, tragus; spinous process of C7, T2, T12, L2, L4) were detected by an optoelectronic instrument. Using dedicated software ̧ the range of motion of the posterior angles of the cervical, thoracic and lumbar spine segments relative to the horizontal axis; the angles between greater trochanterkneeankle and between knee-ankle and the ground; head rotation and tilt; leg and upper limb symmetry, were computed. Results: The head and neck were approximately in line with the horizontal at catch, and extended at finish, with limited horizontal and frontal plane inclinations. Thoracic spine extension during the stroke was on average 68°. Lumbar spine range of motion was on average 59°, and it was smaller in weightier oarsmen. Upper limbs were symmetric, and a complete, symmetric extension of the lower limbs was made. At catch the legs were nearly perpendicular to the ground. Conclusions: The method allowed the measurement of the kinematic characteristics of the body during ergometer rowing. The measurements agreed with conventional technical teaching. Clinical Relevance: Data collected on high-level rowers can provide a set of standard quantitative execution parameters that can be used by coaches as a benchmark for the assessment of technical movements in all rowers.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Comprehensive Biomechanical Study of Ergometer Rowing with Musculoskeletal Models

Rowing is a whole-body exercise that requires co-ordination of the motions of the upper and lower extremities and trunk. Indoor ergometer rowing has long been used by competitive rowers as a training method, but it has also been widely adopted by non-rowers as an exercise for general fitness. A knowledge of the loads in the muscles and joints of the body during ergometer rowing is important not...

متن کامل

Kinematics of the upper and lower extremities in three-dimensions during ergometer rowing

Although the two-dimensional kinematics of the lower and upper extremities and trunk during ergometer rowing has been studied by many [(Nelson & Widule, 1983) (Martindale & Robertson, 1984) (Kaya et al., 1995) (Kaya, 1996) (Kyröläinen & Smith, 1999) (Pudlo, 1999) and (Hawkins, 2000)], the anatomical segment paths and ranges of motion are not reported explicitly in the literature. Nelson and Wid...

متن کامل

A comparison of kinematics and performance measures of two rowing ergometers.

Rowing injuries have been attributed to poor technique, suggesting a need to understand the mechanics of rowing and the influence on technique of different training regimes and ergometers. The aims of this study were to investigate the repeatability of the kinematics of the lumbopelvic region during rowing and to compare these kinematics between rowing on two different ergometers. An electromag...

متن کامل

Scaling concept II rowing ergometer performance for differences in body mass to better reflect rowing in water.

We investigated whether the concept II indoor rowing ergometer accurately reflects rowing on water. Forty-nine junior elite male rowers from a Great Britain training camp completed a 2000 m concept II model C indoor rowing ergometer test and a water-based 2000 m single-scull rowing test. Rowing speed in water (3.66 m/s) was significantly slower than laboratory-based rowing performance (4.96 m/s...

متن کامل

Consistency of pacing and metabolic responses during 2000-m rowing ergometry.

PURPOSE This study investigated the pacing strategy adopted and the consistency of performance and related physiological parameters across three 2000-m rowing-ergometer tests. METHODS Fourteen male well-trained rowers took part in the study. Each participant performed three 2000-m rowing-ergometer tests interspersed by 3-7 d. Throughout the trials, respiratory exchange and heart rate were rec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012