Insertional torque and pullout strength of pedicle screws with or without repositioning: a porcine study.

نویسندگان

  • Chun Ee Tan
  • Margaret Woon Man Fok
  • Keith Dip Kei Luk
  • Kenneth Man Chee Cheung
چکیده

PURPOSE. To evaluate the insertion torque and pullout strength of pedicle screws with or without repositioning. METHODS. 20 fresh porcine lumbar vertebrae of similar size were used. The entry point was at the site just lateral and distal to the superior facet joint of the vertebra, and to a depth of 35 mm. A 6.2-mm-diameter, 35-mm-long pedicle screw was inserted parallel to the superior end plate on one side as control. On the other side, an identical screw was first inserted 10º caudal to the superior end plate, and then repositioned parallel to the superior end plate. The insertional torque and pullout strength were measured. RESULTS. Three of the specimens were excluded owing to pedicle fractures during the pullout test. Repositioned pedicle screws were significantly weaker than controls in terms of the maximum insertional torque (3.20 ± 0.28 vs. 2.04 ± 0.28 Nm, 36% difference, p<0.01) and pullout strength (1664 ± 378 vs.1391 ± 295 N, p<0.01). CONCLUSION. Repositioning pedicle screws should be avoided, especially when the pedicle wall is breached. If repositioning is deemed necessary, augmentation with polymethyl methacrylate or a screw with a larger diameter should be considered.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biomechanical evaluation of relationship of screw pullout strength, insertional torque, and bone mineral density in the cervical spine.

BACKGROUND Understanding of implant failure mechanisms is important in the successful utilization of anterior cervical plates. Many variables influence screw purchase, including the quality of the bone. The purpose of this study was to assess the relationship of screw pullout and screw insertional torque across a wide range of bone mineral densities (BMDs). METHODS A total of 54 cervical vert...

متن کامل

The Pullout Strength of Pedicle Screws Following Redirection After Lateral Wall Breach or End-plate Breach.

STUDY DESIGN Using fresh cadavers, the biomechanical testing were used to examine the pullout strength of each pedicle screw. OBJECTIVE The aim of this study was to evaluate pullout strength of (1) a redirected pedicle screw following lateral wall breach; (2) a redirected pedicle screw following end-plate breach; and (3) a pedicle without redirection after end-plate breach without redirection...

متن کامل

Effect of Pilot Hole Tapping on Pullout Strength and Insertion Torque of Dual Core Pedicle Screws.

OBJECTIVE To evaluate the influence of pilot hole tapping on pullout resistance and insertion torque of pedicle screws with a conical core. METHODS Mechanical tests using a universal testing machine were performed on pedicle screws with a conical core that were inserted into pedicles in the fifth lumbar vertebra of calves. The insertion torque was measured using a torque meter with a capacity...

متن کامل

Comparison of the Pullout Strength of Different Pedicle Screw Designs and Augmentation Techniques in an Osteoporotic Bone Model

Study Design Mechanical study. Purpose To compare the pullout strength of different screw designs and augmentation techniques in an osteoporotic bone model. Overview of Literature Adequate bone screw pullout strength is a common problem among osteoporotic patients. Various screw designs and augmentation techniques have been developed to improve the biomechanical characteristics of the bone-...

متن کامل

A Biomechanical Comparison of Expansive Pedicle Screws for Severe Osteoporosis: The Effects of Screw Design and Cement Augmentation

Expansive pedicle screws significantly improve fixation strength in osteoporotic spines. However, the previous literature does not adequately address the effects of the number of lengthwise slits and the extent of screw expansion on the strength of the bone/screw interface when expansive screws are used with or without cement augmentation. Herein, four designs for expansive pedicle screws with ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of orthopaedic surgery

دوره 22 2  شماره 

صفحات  -

تاریخ انتشار 2014