Modelling of Amperometric Biosensor Used for Synergistic Substrates Determination
نویسندگان
چکیده
In this paper the operation of an amperometric biosensor producing a chemically amplified signal is modelled numerically. The chemical amplification is achieved by using synergistic substrates. The model is based on non-stationary reaction-diffusion equations. The model involves three layers (compartments): a layer of enzyme solution entrapped on the electrode surface, a dialysis membrane covering the enzyme layer and an outer diffusion layer which is modelled by the Nernst approach. The equation system is solved numerically by using the finite difference technique. The biosensor response and sensitivity are investigated by altering the model parameters influencing the enzyme kinetics as well as the mass transport by diffusion. The biosensor action was analyzed with a special emphasis to the effect of the chemical amplification. The simulation results qualitatively explain and confirm the experimentally observed effect of the synergistic substrates conversion on the biosensor response.
منابع مشابه
Effect of Diffusion Limitations on Multianalyte Determination from Biased Biosensor Response
The optimization-based quantitative determination of multianalyte concentrations from biased biosensor responses is investigated under internal and external diffusion-limited conditions. A computational model of a biocatalytic amperometric biosensor utilizing a mono-enzyme-catalyzed (nonspecific) competitive conversion of two substrates was used to generate pseudo-experimental responses to mixt...
متن کاملThe Inkjet Printing of Reducible AgNPs amperometric glucose biosensor Electrodes
The enzymes immobilization of the is crucially effective factor in biosensor preparation. Metal nanoparticles potentially able to immobilize the enzymes according to unique properties including large surface-to-volume ratio, high surface reaction activity, high catalytic efficiency, and strong adsorption ability. A novel and highly sensitive amperometric glucose biosensor was obtained by using ...
متن کاملUrea biosensor based on amperometric pH-sensing with hematein as a pH-sensitive redox mediator.
The natural dye hematein in water solution was used as a pH-sensitive redox-active mediator for amperometric pH-sensing. The electrochemical characteristics were studied using cyclic voltammetry and chronoamperometry. Several types of urea biosensors were constructed with urease on the surface of platinum and graphite composite electrodes or in the bulk of the graphite composite. They were used...
متن کاملDevelopment of a new amperometric biosensor based on polyphenoloxidase and polyethersulphone membrane*
An amperometric biosensor based on the enzyme polyphenoloxidase (PPO), which makes the bioelectrocatalysis of phenolic compounds, was developed and optimized using cathecol as substrate. Polyethersulphone membranes were used for enzyme immobilization. Polyphenoloxidase oxidizes monophenols (cresolase activity) and diphenols (catecholase activity) into the corresponding o-quinones; the o-quinone...
متن کاملAn Amperometric Biosensor Utilizing a Ferrocene-Mediated Horseradish Peroxidase Reaction for the Determination of Capsaicin (Chili Hotness)
Chili hotness is very much dependent on the concentration of capsaicin present in the chili fruit. A new biosensor based on a horseradish peroxidase enzyme-capsaicin reaction mediated by ferrocene has been successfully developed for the amperometric determination of chili hotness. The amperometric biosensor is fabricated based on a single-step immobilization of both ferrocene and horseradish pe...
متن کامل