Evaluation of the Merlin MICRONAUT system for rapid direct susceptibility testing of gram-positive cocci and gram-negative bacilli from positive blood cultures.

نویسندگان

  • Nele Wellinghausen
  • Tim Pietzcker
  • Sven Poppert
  • Syron Belak
  • Nicole Fieser
  • Melanie Bartel
  • Andreas Essig
چکیده

Bloodstream infections are life-threatening conditions which require the timely initiation of appropriate antimicrobial therapy. We evaluated the automated Merlin MICRONAUT system for rapid direct microtiter broth antimicrobial susceptibility testing (AST) of gram-positive cocci and gram-negative bacilli from BACTEC 9240 bottles with positive blood cultures in comparison to the standard method for the Merlin MICRONAUT system. This prospective study was conducted under routine working conditions during a 9-month period. Altogether, 504 isolates from 409 patients and 11,819 organism-antibiotic combinations were evaluated for comparison of direct and standard AST methods. For gram-negative bacilli, direct and standard AST of 110 isolates was evaluated and MIC agreement was found for 98.1% of 2,637 organism-antibiotic combinations. Category (susceptible, intermediate susceptible, resistant [SIR]) agreement was found for 99.0%, with results for 0.04% of combinations showing very major errors, those for 0.2% showing major errors, and those for 0.8% showing minor errors. For gram-positive cocci, 373 isolates were evaluated and MIC agreement was found for 95.6% of 8,951 organism-antibiotic combinations. SIR agreement was found for 98.8%, with results for 0.3% of combinations showing very major errors, those for 0.4% showing major errors, and those for 0.5% showing minor errors. Although the number of tested isolates was limited (n = 33), direct AST of streptococci was performed for the first time, yielding promising results with SIR agreement for 98.6% of 363 organism-antibiotic combinations. In conclusion, direct AST of gram-negative bacilli and gram-positive cocci from positive blood cultures with the MICRONAUT system is a reliable technique that allows for the omission of repeat testing of subcultured isolates. Thereby, it reduces the time to results of blood culture testing and may have a positive impact on patient care.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rapid identification and susceptibility testing using the VITEK 2 system using culture fluids from positive BacT/ALERT blood cultures.

BACKGROUND AND PURPOSE In order to reduce the turnaround time for laboratory diagnosis of bacteremia, the efficacy of identification and antimicrobial susceptibility testing using samples taken directly from positive BacT/ALERT standard aerobic and standard anaerobic blood culture bottles was evaluated. METHODS 160 positive blood culture bottles were examined and incubated at 35 degrees C in ...

متن کامل

Accuracy of the VITEK® 2 system for a rapid and direct identification and susceptibility testing of Gramnegative rods and Gram-positive cocci in blood samples.

The performance of the VITEK® 2 system for direct rapid identification and antimicrobial susceptibility testing of the bacteria responsible for blood infections was determined. The isolates studied included 166 Gram-negative rods and 74 Gram-positive cocci from inpatients. Specially treated monomicrobial samples from positive blood culture bottles were directly inoculated into the VITEK 2 syste...

متن کامل

Direct susceptibility testing with positive BacT/Alert blood cultures by using MicroScan overnight and rapid panels.

Studies were conducted on a method of direct inoculation of MicroScan dried overnight and of rapid panels with positive aerobic blood cultures obtained from the BacT/Alert to determine antimicrobial susceptibilities. Inocula were limited to specimens that appeared unimicrobic on Gram stain. Results were compared to those obtained from panels inoculated following subculture. For 133 gram-negativ...

متن کامل

Evaluation of the Hyplex BloodScreen Multiplex PCR-Enzyme-linked immunosorbent assay system for direct identification of gram-positive cocci and gram-negative bacilli from positive blood cultures.

We evaluated the Hyplex BloodScreen PCR-enzyme-linked immunosorbent assay (ELISA) system (BAG, Lich, Germany), a new diagnostic test for the direct identification of gram-negative bacilli and gram-positive cocci from positive blood cultures, with 482 positive BACTEC 9240 blood culture bottles. The test involves amplification of the bacterial DNA by multiplex PCR and subsequent hybridization of ...

متن کامل

بررسی الگوی مقاومت آنتی بیوتیکی باسیل‌‌های گرم منفی، جدا شده از نمونه‌‌های کشت ادرار مرکز آموزشی و درمانی امام رضا(ع)-کرمانشاه

Received: 14 April, 2009 Accepted: 21 Oct, 2009 Abstract Background & Aims: Antimicrobial resistance among bacterial pathogens is a worldwide problem. The selection of initial treatment is made on an empiric basis and susceptibility testing is important to modify empirical therapy, especially for treatment of common bacterial pathogens. The aim of the present study was to determine the antimi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 45 3  شماره 

صفحات  -

تاریخ انتشار 2007