Assessment of the opening angle of implanted Björk-Shiley prosthetic valves.

نویسندگان

  • G Verdel
  • R M Heethaar
  • G Jambroes
  • T van der Werf
چکیده

A method has been developed in which cineradiography is used for the assessment of the opening angle of implanted Bjork-Shiley prosthetic valves. The method is based on the fact that the ring and the disc, which are known to be circular, appear to be elliptical on x-ray films. The spatial position of the valve can be retrieved from the characteristics of these ellipses when vectoranalysis is applied. The method's accuracy does not depend on the position of the patient with respect to the direction of the x-ray beam. The accuracy of the method was demonstrated with the use of a phantom valve. The difference between the measured and the real opening angle was -0.7 +/- 1.8 degrees (mean +/- SD). Results were reproducible in patients to within -0.1 +/- 1.8 degrees. In 18 patients with normally functioning valves it could be demonstrated with frame-by-frame analysis (interval between frames 20 msec) that the valves opened very rapidly up to about 60 degrees. Closing patterns varied. In one of our patients with valvular thrombosis insufficient valvular opening could be demonstrated by our method before the patient's complaints drew attention to the valvular dysfunction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

DIAGNOSTIC METHODS PROSTHETIC VALVE FUNCTION Assessment of the opening angle of implanted Bjork-Shiley prosthetic valves

A method has been developed in which cineradiography is used for the assessment of the opening angle of implanted Bjork-Shiley prosthetic valves. The method is based on the fact that the ring and the disc, which are known to be circular, appear to be elliptical on x-ray films. The spatial position of the valve can be retrieved from the characteristics of these ellipses when vectoranalysis is ap...

متن کامل

Evaluation of Björk-Shiley prosthetic valves by real-time two-dimensional Doppler echocardiographic flow mapping.

We studied the value of two-dimensional Doppler echocardiographic color flow mapping for identifying normal transvalve flow profiles and valve malfunction in 20 patients with Björk-Shiley prosthetic valves. Seven patients had Björk-Shiley prosthetic valves in the aortic position alone, seven in the mitral position, and six had prosthetic valves in both the aortic and mitral positions. In 10 pat...

متن کامل

Doppler echocardiographic characteristics of normal and dysfunctioning prosthetic valves in the tricuspid and mitral position.

The Doppler echocardiographic characteristics of 70 prosthetic valves in 35 patients are reported. Twenty nine patients had a Björk-Shiley prosthesis in both mitral and tricuspid positions and six had Carpentier-Edwards valves in both sites. Five of the patients had abnormal tricuspid prostheses on the basis of clinical and echocardiographic criteria. Pulsed wave Doppler echocardiography was us...

متن کامل

Twenty-five-year experience with the Björk-Shiley convexoconcave heart valve: a continuing clinical concern.

BACKGROUND The first Björk-Shiley convexoconcave (BSCC) prosthetic heart valves were implanted in 1978. The 25th anniversary provided a stimulus to summarize the research data relevant to BSCC valve fracture, patient management, and current clinical options. METHODS AND RESULTS Published and unpublished data on the risks of BSCC valve fracture and replacement were compiled, and strategies for...

متن کامل

Sound spectroanalytic diagnosis of malfunctioning prosthetic heart valve.

Sound spectroanalysis was carried out for diagnosis of malfunctioning prosthetic heart valves in 50 cases, which consisted of 31 mitral, 14 aortic, 4 mitral+aortic and 1 tricuspid valve replacements with the age ranging from 17 to 57 years. Types of prosthetic valves used in this series were Starr-Edwards silicon ball valves, metal ball valves, disc valves, Kay-Shiley valves, Smeloff-Cutter val...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 68 2  شماره 

صفحات  -

تاریخ انتشار 1983