Rapid sequential visualization of the heart and great vessels in man using the wide-field anger scintillation camera. Radioisotope-angiography following the injection of technetium-99m.

نویسندگان

  • D T Mason
  • W L Ashburn
  • J C Harbert
  • L S Cohen
  • E Braunwald
چکیده

The recent development of the instantaneously sensing Anger scintillation camera, capable of recording wide-field radioisotope images from the precordium, and a system for video storage and analysis has provided a means of visualizing the anatomic and hemodynamic features of the heart and great vessels without the hazards involved in introducing a radiopaque agent. Sodium pertechnetate (ODmTc04-) produces no cardiocirculatory effects or untoward actions and delivers only 0.13 rads of total body radiation. Following injection, the rapidly changing distribution of radioactivity within the heart is recorded by the scintillation camera-television system which includes no inherent dead time or overlap of the scanned field from frame to frame. Video tape replay is available immediately and sequential integrated pictures are possible at any rate up to 60 sec. Radioisotope images of longer intervals are easily obtained by the integration of successive stop-action fields reproduced on a high resolution television monitor and photographed on rapidly developed film. In addition, the replay may be gated and tracked, allowing selected phases to be integrated and time-concentration curves of blood flow. Five to 10 millicuries of 99mTcO4in 2 to 8 cc were rapidly injected into selected cardiac chambers at the time of diagnostic catheterization in 50 patients with a variety of congenital and acquired forms of heart disease. Movement of radioisotope closely reflected the hemodynamic alterations caused by these conditions, as determined by standard contrast angiocardiography. The radioisotope-angiocardiogram provides a new approach for visualization of the cardiovascular system, does not require the use of radiopaque medium, is safer than angiography, and does not disturb circulatory function.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rapid Sequential Visualization of the Heart and Great Vessels in Man Using the Wide-Field Anger Scintillation Camera

The recent development of the instantaneously sensing Anger scintillation camera, capable of recording wide-field radioisotope images from the precordium, and a system for video storage and analysis has provided a means of visualizing the anatomic and hemodynamic features of the heart and great vessels without the hazards involved in introducing a radiopaque agent. Sodium pertechnetate (ODmTc04...

متن کامل

Measurement of heart chamber volumes by analysis of dilution curves simultaneously recorded by scintillation camera.

SUMMARY After a peripheral injection of Technetium-99m, an Anger scintillation camera placed over the precordium of nine patients without and three patients with hemodynamic abnormalities was used to record in rapid sequence the flow of the injected material through the central circulatory system. After the data were processed as sequential frames of digitized spatial matrices, the position of ...

متن کامل

The Feasibility of Thyroid Treatment with 99mTc Radiopharmaceuticals and Stable Iodine as Contrast Agent Using MCNP Simulation Code

Introduction: Nowadays, radioisotopes have a lot of therapeutic and diagnostic applications in nuclear medicine. The technetium-99m radioisotope is widely used in the diagnostic field. The technetium-99m radioisotope is widely used in the diagnostic field. In this study, in order to increase the absorption dose in thyroid cancer cells, the radioactive drug technetium-99m which ...

متن کامل

Assessment of molybdenum breakthrough levels in molybdenum-99/technetium-99m generators: One year experience at NIMRA Jamshoro Pakistan

Background: Technetium-99m radioisotope is the backbone of any nuclear medicine institute. This radioisotope is acquired by the elution of Molybdenum-99/Technetium-99m generator which emits 141 keV gamma ray and having 6.04 hour half-life. Occasionally the contents of Molybdenum-99 may mix up with elute, which may affect image quality and patients may receive higher doses than recommended. This...

متن کامل

Determination of Optimum Planar Imaging Parameters for Small Structures with Diameters Less Than the Resolution of the Gamma Camera

Introduction: The limited spatial resolution of the gamma camera hinders the absolute quantification of planar images of small structures. The imaged structures are affected by partial volume effects (PVEs), which can spread activity and lead to underestimation of the regional distribution.  The use of optimum planar parameters reduces the impact of the limited spatial resolution of the gamma c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 39 1  شماره 

صفحات  -

تاریخ انتشار 1969