Focus on Dynamic Contrast-enhanced in Breast Cancer
نویسنده
چکیده
The analysis of breast tissues was related to the origins of medical use of nuclear magnetic resonance (NMR) since Damadian’s experiments during the Seventies of the last century [1]. However, clinical breast magnetic resonance imaging (MRI) studies using standard T1-, proton density-, and T2weighted sequences were disappointing. A dramatic change was obtained in 1986, when S.H. Heywang firstly obtained contrast-enhanced (CE) MR images after intravenous administration of gadopentetate dimeglumine (Gd-DTPA) [2]. The availability of faster T1-weighted gradient-echo spoiled sequences allowed for dynamic imaging, permitting the combination of morphologic and dynamic parameters, the latter classified by C.K. Kuhl in 1999 [3] as continuous increase (type 1), plateau (type 2), and washout (type 3). Two ways for breast MRI were followed on the two sides of Atlantic Ocean during about 15 years: 1) in Europe, dynamic CE imaging with 60-90-s temporal resolution and a relatively lower spatial resolution, preferentially using axial or coronal planes; 2) in the United States, non-dynamic CE fat-saturated imaging with high spatial resolution and low temporal resolution, preferentially using sagittal planes. Thereafter, these two ways were substantially unified by protocols which permit both high spatial resolution and sufficient temporal resolution (up to 120 s), with or without fat-saturation (axial or sagittal currently preferred to coronal planes). On the other hand, clinical research studies on single-voxel proton MR spectroscopy (MRS) were performed using the choline peak as a marker of malignancy [4], while during the Nineties MR-guided breast needle biopsy became available, finally filling a relevant gap for a breast imaging modality in clinical practice [5]. In 2003, the American College of Radiology extended to MRI the Breast Imaging and Reporting Data System (BI-RADS) [6], promoting a standardization of lexicon and interpretation, including the classification into the three types of dynamic curves. Thus, dynamic CE MRI has been included in the standardized interpretation of breast MRI, at least in terms of qualitative visual evaluation Afterwards, especially in the last decade, technical developments such as strong and rapid field gradients, multichannel dedicated coils and parallel imaging, high-field (3T) magnets, new dedicated sequences, including those for diffusion-weighted imaging and 2D/3D multi-voxel proton MRS, made breast MRI technology more and more robust and attractive in terms of multiple options offered to clinicians and researchers. However, dynamic CE MRI remains as the standard of care when an MRI study of the breast has to be performed with the only exception of the evaluation of breast implant integrity. Notwithstanding a growing evidence for a high diagnostic performance of dynamic CE breast MRI, including high sensitivity not only for invasive cancers but also for ductal carcinoma in situ, a long-standing false “mantra”, frequently repeated also by breast radiologists, acted against its clinical use: “Breast MRI is a diagnostic tool with high sensitivity but with low specificity”. This affirmation implied a large number of MRI false positives and strongly limited the potential application of this technique to a screening setting, due to a great fear of a deluge of “recalls”, i.e. of cases of healthy women requiring further investigations. In 2008, the large meta-analysis by Peters et al (also including many old studies performed with today outdated, non-dynamic, technical protocols) stopped this discussion: 90% sensitivity and 72% specificity [7]. As a matter of fact, when breast MRI was applied to high-risk screening, sensitivity was over 90%, specificity went up to 97%, and the positive predictive value (62%) was not significantly different than that of mammography or ultrasound [8]. However, we should always consider that the diagnostic performance of whatever test depends on many factors other than technical quality and readers’ experience and skill, especially including patient selection and clinical setting. Last but not least, new contrast materials, different from those traditionally used due to a higher T1-relaxivity and/or concentration, are now entering dynamic CE breast MRI with promising results in terms of a higher diagnostic performance [9, 10]. A large debate among breast cancer specialists is open on indications for dynamic CE breast MRI [11]. Some indications are now accepted: high-risk screening, carcinoma unknown primary, breast implant integrity evaluation (using unenhanced specialized sequences), evaluation of the effect of neoadjuvant chemotherapy (NAC), and evaluation of suspected recurrence when conventional imaging is inconclusive and needle tissue sampling cannot be performed. Other indications, especially preoperative MRI, are under discussion [11-13]. New indications such as nipple discharge [14] and evaluation of lesions with uncertain malignant potential at mammographyor US-guided
منابع مشابه
Automatic Prostate Cancer Segmentation Using Kinetic Analysis in Dynamic Contrast-Enhanced MRI
Background: Dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) provides functional information on the microcirculation in tissues by analyzing the enhancement kinetics which can be used as biomarkers for prostate lesions detection and characterization.Objective: The purpose of this study is to investigate spatiotemporal patterns of tumors by extracting semi-quantitative as well as w...
متن کاملA Novel Biocompatible Nanoprobe Based on Lipoproteins for Breast Cancer Cell Imaging
Objective(s): Contrast-enhanced magnetic resonance imaging (MRI) of breast cancer provides valuable data on the disease state of patients. Biocompatible nanoprobes are expected to play a pivotal role in medical diagnosis in the future owing to their prominent advantages. The present study aimed to introduce a novel biocompatible nanoprobe based on lipoproteins for breast cancer cell imaging.<br...
متن کاملEffect of Bias in Contrast Agent Concentration Measurement on Estimated Pharmacokinetic Parameters in Brain Dynamic Contrast-Enhanced Magnetic Resonance Imaging Studies
Introduction: Pharmacokinetic (PK) modeling of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is widely applied in tumor diagnosis and treatment evaluation. Precision analysis of the estimated PK parameters is essential when they are used as a measure for therapy evaluation or treatment planning. In this study, the accuracy of PK parameters in brain DCE...
متن کاملContrast Enhancement of Mammograms for Rapid Detection of Microcalcification Clusters
Introduction Breast cancer is one of the most common types of cancer among women. Early detection of breast cancer is the key to reducing the associated mortality rate. The presence of microcalcifications clusters (MCCs) is one of the earliest signs of breast cancer. Due to poor imaging contrast of mammograms and noise contamination, radiologists may overlook some diagnostic signs, specially t...
متن کاملEvaluation of the accuracy of dynamic contrast enhanced MRI in the diagnosis of invasive prostate neoplasm using pathological findings
Background: Prostate cancer is the most common malignancy in men and the second leading cause of death in all countries of the world. The exact mechanism of prostate cancer is not known. On the other hand, early detection of prostate cancer can lead to a complete cure. Several clinical experiments including Digital Rectum Examination (DRE), biochemistry such as Prostate Specific Antigen (PSA), ...
متن کاملA Bi-Functional Targeted P28-NRC Chimeric Protein with Enhanced Cytotoxic Effects on Breast Cancer Cell Lines
One of the emerging therapeutic strategies for targeted therapy of cancer is the use of chimeric proteins. The p28 peptide has the ability of selective entrance and activating apoptosis in breast cancer cells. The NRC antimicrobial peptide showed cytotoxic activity on various breast cancer including drug-resistant variants but also normal cell lines. Here we designed a chimeric protein consiste...
متن کامل