Continuous wave laser diodes enable fast optoacoustic imaging

نویسندگان

  • Antonios Stylogiannis
  • Ludwig Prade
  • Andreas Buehler
  • Juan Aguirre
  • George Sergiadis
  • Vasilis Ntziachristos
چکیده

Pulsed laser diodes may offer a smaller, less expensive alternative to conventional optoacoustic laser sources; however they do not provide pulse rates faster than a few tens of kHz and emit at wavelengths only within the near-infrared region. We investigated whether continuous wave (CW) laser diodes, which are available in visible and near-infrared regions, can be good optoacoustic light sources when overdriven with a peak current >40-fold higher than the CW absolute maximum. We found that overdriven CW diodes provided ∼10 ns pulses of ∼200 nJ/pulse and repetition rates higher than 600 kHz without being damaged, outperforming many pulsed laser diodes. Using this system, we obtained images of phantoms and mouse ear and human arm in vivo, confirming their use in optoacoustic imaging and sensing.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Modeling Photoacoustic Tomography using k-Wave

Photoacoustic tomography (PAT) is a hybrid imaging technique that offers similar medical potential as ultrasound and optical imaging. Although efforts to innovate Photoacoustic scanners have been scarce, newer developments such as k-Wave will enable their optimal imaging capability. Despite k-Wave’s ability to simulate PAT, few researchers utilize this technology. Thus, this project explored th...

متن کامل

Noninvasive optoacoustic online retinal temperature determination during continuous-wave laser irradiation.

The therapeutic effect of most retinal laser treatments is initiated by a transient temperature increase. Although crucial to the effectiveness of the treatment, the temperature course is not exactly known due to individually different tissue properties. We develop an optoacoustic method to determine the retinal temperature increase in real time during continuous-wave (cw) laser irradiation, an...

متن کامل

Iterative reconstruction method for three-dimensional optoacoustic imaging

Three-dimensional optoacoustic imaging uses detection of laser-generated thermoelastic waves with an ultrasound sensor array. Integrated acoustic signals (velocity potentials) are back projected into the source volume to give a map of absorbed laser energy. Since the number of array elements and the receiving solid angle are limited, radial back projection produces artifacts such as back projec...

متن کامل

Laser Optoacoustic Imaging for Breast Cancer Diagnostics: Limit of Detection and Comparison with X-ray and Ultrasound Imaging

Laser optoacoustic imaging is a promising diagnostic technique for early breast cancer detection. Capability of laser optoacoustic imaging for visualization of small spherical tumor phantoms located within the bulk collagen gels was studied. The experiments were performed with breast phantoms made of optically turbid collagen gel. Optical properties of the phantom resembled the optical properti...

متن کامل

Noninvasive optoacoustic temperature determination at the fundus of the eye during laser irradiation.

In all fundus laser treatments of the eye, the temperature increase is not exactly known. In order to optimize treatments, an online temperature determination is preferable. We investigated a noninvasive optoacoustic method to monitor the fundus temperature during pulsed laser irradiation. When laser pulses are applied to the fundus, thermoelastic pressure waves are emitted, due to thermal expa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2018