Marginal fit analysis of premachined and castable UCLA abutments.
نویسندگان
چکیده
This study evaluated the fit between implants and premachined and castable UCLA abutments. All plastic specimens were cast using the conventional technique in accordance with the manufacturer's instructions. Five specimens of each experimental group were measured for vertical and horizontal gaps by scanning electronic microscopy (Phillips XL 30 model, Holland). Gold UCLA (vertical gap: 2.15 microm, horizontal gap: 11.30 microm) and castable rotational UCLA (vertical gap: 14.91 microm, horizontal gap: 59.41 microm) groups showed the lowest and highest mean values, respectively (Neodent, Curitiba, Parana, Brazil). In general, the castable UCLA abutments showed poorer marginal fit than the premachined abutments.
منابع مشابه
Effect of Cast Rectifiers on the Marginal Fit of Ucla Abutments
OBJECTIVES This study assessed the effect of cast rectifiers on the marginal misfit of cast UCLA abutments compared to premachined UCLA abutments. The influence of casting and porcelain baking on the marginal misfit of these components was also investigated. METHODS Two groups were analyzed: test group - 10 cast UCLA abutments, finished with cast rectifier and submitted to ceramic application...
متن کاملProsthetic laboratory influence on the vertical misfit at the implant/UCLA abutment interface.
An inadequate fit at the abutment/implant interface can generate mechanical and biological problems. The laboratorial stages could induce misfit in such interface when the castable UCLA abutment type is used. The purpose of this study was to comparatively evaluate the performance of three prosthetic laboratories (Labs A, B and C) by vertical fit analysis of castable UCLA abutments on the castin...
متن کاملMarginal discrepancy of screw-retained and cemented metal-ceramic crowns on implants abutments.
This in vitro study quantified the marginal discrepancy of the implant-to-prosthetic-crown interface on nonsubmerged dental implants restored with either a cemented or a screw-retained approach. Metal-ceramic crowns were fabricated for 20 ITI 4.1 x 10 mm solid-screw titanium implants. Ten implants received octa abutments and screw-retained crowns fabricated on premachined gold cylinders. The re...
متن کاملEffect of casting procedures on screw loosening in UCLA-type abutments.
BACKGROUND Screw loosening of implant restorations continues to be a complication in implant prosthodontics. Screw joints are subjected to a loss of initially applied torque because of friction and component misfit. It has been suggested that the loss of applied torque is less in machined metal abutments than in cast plastic abutments. PURPOSE This study compared the loss of applied torque (d...
متن کاملبررسی میزان کاهش تورک در اباتمنتهای کست شونده با آلیاژ کروم کبالت پس از اعمال بارگذاری دورهای
Background and Aims: For the clinical success of implant-retained prostheses, fitness of matching components and stability of the applied torque to the implant-abutment assembly under dynamic occlusal loading is essential. The aim of this study was to evaluate the torque loss in Co-Cr castable abutments after cyclic loading. Materials and Methods: 10 castable abutments were cast in Co-Cr alloy...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Acta odontologica latinoamericana : AOL
دوره 22 2 شماره
صفحات -
تاریخ انتشار 2009