Cumulative radiation dose in patients admitted with subarachnoid hemorrhage: a prospective study using a self-developing film badge.
نویسندگان
چکیده
BACKGROUND AND PURPOSE While considerable attention has been directed to reducing the x-ray dose of individual imaging studies, there is little information available on the cumulative dose during imaging-intensive hospitalizations. We used a radiation-sensitive badge on 12 patients admitted with SAH to determine if this approach was feasible and to measure the extent of their x-ray exposure. MATERIALS AND METHODS After obtaining informed consent, we assigned a badge to each of 12 patients and used it for all brain imaging studies during their ICU stay. Cumulative dose was determined by quantifying exposure on the badge and correlating it with the number and type of examinations. RESULTS The average skin dose for the 3 patients who had only diagnostic DSA without endovascular intervention was 0.4 Gy (0.2-0.6 Gy). The average skin dose of the 8 patients who had both diagnostic DSA and interventions (eg, intra-arterial treatment of vasospasm and coiling of aneurysms) was 0.9 Gy (1.8-0.4 Gy). One patient had only CT examinations. There was no effort made to include or exclude the badge in the working view during interventions. CONCLUSIONS It is feasible to incorporate a film badge that uses a visual scale to monitor the x-ray dose into the care of hospitalized patients. Cumulative skin doses in excess of 1 Gy were not uncommon (3/12) in this group of patients with acute SAH. This approach could provide a measure of the cumulative dose and is a convenient tool to quantify the effect of dose-reduction strategies.
منابع مشابه
A three-year survey of film badge service performance in Iran
An extensive study was undertaken to Investigate on the overall film badge service performance with which occupational radiation, exposures are reported In Iran, The study involved the analysis of film badges exposed to x-and gamma rays and beta particles. For test exposures, x-rays between 60 and 140 KVPCo-60 gamma radiation and Sr-90 beta particles were used. The actual delivered dose equival...
متن کاملEffect of Exposure to Ionizing Radiation on Biomarker of Oxidative Damage of DNA
Introduction: one of the most important complications of exposure to ionizing radiation is emergence of cancer tumors, which happens as a result of oxidative DNA. Therefore, the present study was conducted, aimed to measuring 8-DIHYDROxy- 2’- DEOXYGUANOSINE (8-OHdG) level in radiographers’ urine as oxidative damage biomarker, as well as comparing this biomarker with cumulative effective doses....
متن کاملCumulative radiation dose during hospitalization for aneurysmal subarachnoid hemorrhage.
BACKGROUND AND PURPOSE Radiation exposure from neurointerventional procedures and diagnostic neuroimaging can be substantial, with many recommendations offered to guide the interventionalist in the conscientious use of ionizing radiation. Patients presenting with an aneurysmal subarachnoid hemorrhage can undergo multiple imaging procedures during a prolonged hospital course. Therefore, we revie...
متن کاملComplications of Subarachnoid Hemorrhage in Patients Admitted to Imam Khomeini Hospital in Urumia
Background and Aim: Secondary complications management of Subarachnoid Hemorrhage (SAH) is one of the therapeutic challenging issues during ICU[A1] admission. The complications of patients with SAH admitted to the ICU of Imam Khomeini Hospital of Urumia were investigated in this study. Methods and Materials/Patients: In this descriptive study, the clinical complications of the patients with ...
متن کاملEvaluation of Occupational Radiation Status and Validity of Individual Dose and Eye Lens Assessment Using Single Film Dosimeter for Angiographic Staff in Iran
Background and Aim: In angiography, the lens of the eye may be exposed to radiation and cause cataracts. In Iran, at present, only a single film dosimeter is used under the lead-apron to evaluate individual doses. The aim of this study was to investigate the status of occupational radiation as well as the validity of measuring the dose of the whole body of individuals and eye lenses using a sin...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 31 10 شماره
صفحات -
تاریخ انتشار 2010