Visual Outcomes and Refractive Status after Combined Silicone Oil Removal/Cataract Surgery with Intraocular Lens Implantation

نویسندگان

  • Hussain F Al-Habboubi
  • Waseem Al-Zamil
  • Ali A Al-Habboubi
  • Rajiv Khandekar
چکیده

Purpose To evaluate refractive status and identify predictors of surgical success following a combined silicone oil removal/cataract surgery with intraocular lens (IOL) implantation procedure. Methods In this single-armed, retrospective study, we reviewed patients who underwent vitreoretinal surgery followed by a combined silicone oil removal/cataract surgery procedure between 2009 and 2013. Preoperative data included patient demographics, refractive status, IOL power, and axial length (measured with the IOL Master). Postoperative data were obtained from the 8-week follow-up visit and from the last follow-up visit attended that included refractive error (RE) evaluation (e.g., myopic, hyperopic, and astigmatic). Associations between variables and refractive status were examined. Blindness was defined as a best-corrected visual acuity (BCVA) worse than 3/60. Results Nighty-eight eyes were ultimately included in analyses. Following surgery, 37.0% of eyes achieved BCVA better than 6/18. The incidence of blindness (BCVA worse than 3/60) was reduced from 47.0% before surgery to 17.3% after surgery. Additionally, 33.7% of eyes did not require refractive correction. Forty-two percent of eyes were under-corrected (>0.5 D hyperopia) following surgery. Age, gender, silicone oil viscosity, axial length, IOL type, initial vitreoretinal pathology, surgeon, and IOL calculation formula were not significantly associated with surgical outcomes (all P > 0.05). Conclusion A combined silicone oil removal/cataract surgery with IOL implantation procedure restored functional vision in approximately one-third of cases. However, nearly half of patients were under-corrected. Unfortunately, we did not identify any factors that predicted surgical success.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Refractive Change Caused Silicone Oil Adhesion to the Intraocular Lens Following Nd:YAG Posterior Capsulotomy

A 32-year-old female who had undergone the silicone oil removal procedure presented with visual disturbance in her left eye. Several months previous, she had cataract surgery in a private clinic, and a month later she had a Nd:YAG laser procedure for posterior capsulotomy. The slit-lamp examination revealed silicone oil droplets that had adhered to the intraocular lens where the posterior capsu...

متن کامل

Intraoperative biometry for intraocular lens (IOL) power calculation at silicone oil removal.

PURPOSE Cataract development is common following retinal detachment surgery that necessitates silicone oil injection. Intraocular lens (IOL) power calculation in the presence of silicone oil is challenging for many reasons. The authors evaluated the accuracy of intraoperative biometry during cataract surgery in silicone-filled eyes. METHODS Twelve cases of cataract in eyes filled with silicon...

متن کامل

Timing and outcomes after silicone oil removal in proliferative vitreoretinopathy: a retrospective clinical series

OBJECTIVE To evaluate anatomical and functional outcomes after silicone oil extraction in patients with retinal detachment and proliferative vitreoretinopathy in an eye care referral center in Joinville, SC, southern Brazil. METHODS Retrospective, noncomparative study of patients with retinal detachment and posterior proliferative vitreoretinopathy followed up after silicone oil removal. Prop...

متن کامل

Bilateral cataract after phakic posterior chamber top hat-style silicone intraocular lens.

BACKGROUND New strategies have been developed for surgical treatment of high myopia. Recently, implantation of minus power posterior chamber intraocular lenses (IOL) into phakic eyes has been introduced. METHODS We report a 37 year-old female patient who developed bilateral anterior subcapsular cataract 7 years after minus-power, top hat-style silicone posterior chamber IOL implantation in Ru...

متن کامل

Visual and Refractive Results of Cataract Surgery by Phacoemulsification Method in Patients with Keratoconus

Purpose: To examine the visual and refractive results of cataract surgery by phacoemulsification method in patients with keratoconus. Methods: In this retrospective study, the files of patients with keratoconus, who underwent phacoemulsification between 2008 and 2017, were evaluated. The intraocular lens power calculation formula was SRK/T. Post-operative visual and refractive results were anal...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2018