Clinical Outcome of Inter-Proximal Papilla between a Tooth and a Single Implant Treated with CAD/CAM Abutments: a Cross-Sectional Study
نویسندگان
چکیده
OBJECTIVES The aim of this study was to assess the clinical outcomes achieved with Computer-Assisted Design/Computer-Assisted Manufacturing implant abutments in the anterior maxilla. MATERIAL AND METHODS Nineteen patients with a mean age of 41 (range form 26 to 63) years, treated with 21 single tooth implants and 21 Computer-Assisted Design/Computer-Assisted Manufacturing (CAD/CAM) abutments in the anterior maxillary region were included in this study. The patients followed 4 criteria of inclusion: (1) had a single-tooth implant in the anterior maxilla, (2) had a CAD/CAM abutment, (3) had a contralateral natural tooth, (4) the implant was restored and in function for at least 6 months up to 2 years. Cases without contact point were excluded. Presence/absence of the interproximal papilla, inter tooth-implant distance (ITD) and distance from the base of the contact point to dental crest bone of adjacent tooth (CPB) were accessed. RESULTS Forty interproximal spaces were evaluated, with an average mesial CPB of 5.65 (SD 1.65) mm and distal CPB of 4.65 (SD 1.98) mm. An average mesial ITD of 2.49 (SD 0.69) mm and an average distal ITD of 1.89 (SD 0.63) mm were achieved. Papilla was present in all the interproximal spaces accessed. CONCLUSIONS The restoration of dental implants using CAD/CAM abutments is a predictable treatment with improved aesthetic results. These type of abutments seem to help maintaining a regular papillary filling although the variations of the implant positioning or the restoration teeth relation.
منابع مشابه
Stock Versus CAD/CAM Customized Zirconia Implant Abutments – Clinical and Patient‐Based Outcomes in a Randomized Controlled Clinical Trial
BACKGROUND Single-tooth replacement often requires a prefabricated dental implant and a customized crown. The benefits of individualization of the abutment remain unclear. PURPOSE This randomized controlled clinical trial aims to study potential benefits of individualization of zirconia implant abutments with respect to preservation of marginal bone level and several clinical and patient-base...
متن کاملUniversity of Groningen Stock Versus CAD/CAM Customized Zirconia Implant Abutments - Clinical and Patient- Based Outcomes in a Randomized Controlled Clinical Trial Schepke,
Background: Single-tooth replacement often requires a prefabricated dental implant and a customized crown. The benefits of individualization of the abutment remain unclear. Purpose: This randomized controlled clinical trial aims to study potential benefits of individualization of zirconia implant abutments with respect to preservation of marginal bone level and several clinical and patient-base...
متن کاملبررسی مقایسهای مشخصات بافت نرم اطراف ایمپلنت با دندان
Background and Aim: Soft tissue condition around dental implant is an essential part for long term healthy and esthetic outcome. The aim of this study was to compare soft tissue dimensions between implant supported single tooth replacement and the contra-lateral natural tooth. Materials and Methods: This retrospective study was performed on dentate patients treated with anterior single tooth...
متن کاملIncidence of undetected cement on CAD/CAM monolithic zirconia crowns and customized CAD/CAM implant abutments. A prospective case series.
OBJECTIVE The aim of this study was to assess the frequency of cement residues after cementation of CAD/CAM monolithic zirconia crowns on customized CAD/CAM titanium abutments. MATERIALS AND METHODS Sixty premolars and molars were restored on Astra Tech Osseospeed TX™ implants using single monolithic zirconia crowns fixed on two types of custom-made abutments: Atlantis™ titanium or Atlantis™ ...
متن کاملAssessment of reliability of CAD-CAM tooth-colored implant custom abutments.
STATEMENT OF PROBLEM Information is lacking about the fatigue resistance of computer-aided design and computer-aided manufacturing (CAD-CAM) tooth-colored implant custom abutment materials. PURPOSE The purpose of this in vitro study was to investigate the reliability of different types of CAD-CAM tooth-colored implant custom abutments. MATERIAL AND METHODS Zirconia (Lava Plus), lithium disi...
متن کامل