Live/Real time three-dimensional transesophageal echocardiography in percutaneous closure of atrial septal defects.

نویسندگان

  • Maneesha Bhaya
  • Ferit Onur Mutluer
  • Edward Mahan
  • Luke Mahan
  • Ming C Hsiung
  • Wei-Hsian Yin
  • Jeng Wei
  • Shen-Kou Tsai
  • Guang-Yu Zhao
  • Manish Pradhan
  • Rajesh Beniwal
  • Deepak Joshi
  • Fatemeh Nabavizadeh
  • Amitoj Singh
  • Navin C Nanda
چکیده

OBJECTIVES This study assessed the ability of live/real time three-dimensional transesophageal echocardiography (3DTEE) in measuring (1) atrial septal defect (ASD) maximum dimension, area, and adjacent rim size, (2) ASD occluder left and right atrial disk size, (3) length of contact between the left atrial (LA) disk and the aorta, and in (4) assessing device related complications such as residual shunt, device embolization, and device encroachment upon adjacent cardiac structures. MATERIALS AND METHODS 3DTEE images acquired during percutaneous ASD closure by the Amplatzer Septal Occluder in 15 adult patients were retrospectively analyzed. Offline analysis was done using both the Philips 5500 ultrasound system and Philips QLAB software. 3D color flow Doppler images were used to assess residual ASD shunting. RESULTS The Philips 5500 and Philips QLAB measurements correlated well for ASD maximum dimension and area measurements. The Philips QLAB 3DTEE disk size measurements also correlated well with the manufacturer obtained sizes. The aortic rim was deficient in 7 of the 15 patients, and the mean ASD occluder device size was 4 mm greater than the mean ASD maximum dimension. The LA occluder disk was in contact with the aorta throughout the cardiac cycle in 12 of the 15 patients, and the LA occluder disk size correlated significantly with the contact length with the aorta. CONCLUSION Most of the patients demonstrated contact between the LA occluder disk and the aorta throughout the cardiac cycle. 3DTEE may be useful in identifying patients at greater risk for aortic erosion.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Live/Real Time Three-Dimensional Trans Esophageal Echocardiographic Findings in Amplatzer ASD Closure Devices in Adults

Six female patients aged from 19 to 73 years, with ostium secundum atrial septal defect underwent closure procedure with Amplatzer septal occluder device. Three-dimensional Echocardiography (3D-TEE) was done during the procedure or one day after the procedure. 3D-TEE provides incremental value over Two- dimensional trans-esophageal echocardiography in measuring Amplatzer septal occluder disc si...

متن کامل

Real-time three-dimensional transesophageal echocardiography is useful for percutaneous closure of multiple secundum atrial septal defects.

INTRODUCTION The purpose of this study was to investigate the clinical value of real-time three-dimensional transesophageal echocardiography (RT-3D-TEE) for percutaneous transcatheter closure of multiple secundum atrial septal defects (ASDs) using a Chinese domestic occluder device. METHODS From July 2008 to September 2011, 37 patients (mean age 28.4 ± 9.7 years; 24 females) with multiple sec...

متن کامل

Percutaneous closure of multiple secundum atrial septal defects using 3 amplatzer atrial septal occluder devices: evaluation by live transthoracic 3-dimensional echocardiography.

A previously healthy 12-year-old boy was admitted to the hospital with acute pneumonitis. On admission, a heart murmur was detected. The transthoracic echocardiogram showed multiple secundum atrial septal defects with left-toright shunt and signs of right ventricular volume overload. He underwent right cardiac catheterization and transesophageal echocardiogram (transesophageal echocardiography)...

متن کامل

Cryptogenic stroke after percutaneous closure of an atrial septal defect.

We present the case of a patient who underwent a percutaneous secundum atrial septal defect (ASD II) closure with an undersized septal occluder device. One week and one month later she experienced two transient ischemic attacks. Three-dimensional transesophageal echocardiography (TEE) revealed a residual patent foramen ovale (PFO) with a positive Valsalva bubble test. She underwent a second pro...

متن کامل

Successful percutaneous closure of a residual atrial septal defect due to device failure.

A 39-year-old woman underwent uneventful percutaneous occlusion of an ostium secundum atrial septal defect (ASD) with a 22 mm Ultrasept ASD Occluder®. Transesophageal echocardiography (TEE) performed two years after implantation revealed a de novo residual left-to-right shunt through the correctly implanted device. Three-dimensional transesophageal echocardiography (3D TEE) further clarified th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Echocardiography

دوره 30 3  شماره 

صفحات  -

تاریخ انتشار 2013