Effect of Sensor Directionality on Photoacoustic Imaging: A Study Using the k-Wave Toolbox

نویسندگان

  • B. T. Cox
  • Alexander A. Oraevsky
  • Lihong V. Wang
چکیده

Most image reconstruction algorithms for biomedical photoacoustic tomography make the assumption that the optically-generated ultrasonic waves are recorded by pressure detectors with an omni-directional response. In other words, the detectors are assumed to sample the pressure field exactly at a point. In practice this is rarely the case as real detectors have a finite size and often respond not purely to pressure changes but to some combination of acoustic pressure and pressure gradient (or other derivatives). This can make them less sensitive to pressure waves at some angles. The effect of this sensor directionality on photoacoustic tomography was considered here for the case of time-reversal image reconstruction. The ultrasound simulation toolbox k-Wave was used to perform the study.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Modeling Photoacoustic Tomography using k-Wave

Photoacoustic tomography (PAT) is a hybrid imaging technique that offers similar medical potential as ultrasound and optical imaging. Although efforts to innovate Photoacoustic scanners have been scarce, newer developments such as k-Wave will enable their optimal imaging capability. Despite k-Wave’s ability to simulate PAT, few researchers utilize this technology. Thus, this project explored th...

متن کامل

Advanced photoacoustic image reconstruction using the k-Wave toolbox

Reconstructing images from measured time domain signals is an essential step in tomography-mode photoacoustic imaging. However, in practice, there are many complicating factors that make it difficult to obtain high-resolution images. These include incomplete or undersampled data, filtering effects, acoustic and optical attenuation, and uncertainties in the material parameters. Here, the process...

متن کامل

B-Mode Photoacoustic Imaging using Linear Array: Numerical Study for Forward-Backward Minimum Variance Beamformer Combined with Delay-Multiply-and-Sum

Photoacoustic imaging (PAI) is a promising medical imaging modality which provides the resolution of Ultrasound (US) and the contrast of Optical imaging modalities. One of the most important challenges in PAI is image formation, especially in the case that a linear-array US transducer is used for data acquisition. This is due to the fact that in the linear-array scenario, there is only 60 degre...

متن کامل

k-Wave: MATLAB toolbox for the simulation and reconstruction of photoacoustic wave fields.

A new, freely available third party MATLAB toolbox for the simulation and reconstruction of photoacoustic wave fields is described. The toolbox, named k-Wave, is designed to make realistic photoacoustic modeling simple and fast. The forward simulations are based on a k-space pseudo-spectral time domain solution to coupled first-order acoustic equations for homogeneous or heterogeneous media in ...

متن کامل

The advantage of using a diode laser instead of a Q-switched laser in photoacoustic imaging of tissues

Photoacoustic (PA) imaging of biological tissues using laser diodes instead of conventional Q switched pulsed systems provides an attractive alternative for biomedical applications. However, the relatively low energy of laser diodes operating in the pulsed regime, results in generation of very weak acoustic waves, and low signal-to-noise ratio (SNR) of the detected signals. This problem can be ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010