Implant stability and bone remodeling up to 84 days of implantation with an initial static strain. An in vivo and theoretical investigation
نویسندگان
چکیده
OBJECTIVES When implants are inserted, the initial implant stability is dependent on the mechanical stability. To increase the initial stability, it was hypothesized that bone condensation implants will enhance the mechanical stability initially and that the moderately rough surface will further contribute to the secondary stability by enhanced osseointegration. It was further hypothesized that as the healing progresses the difference in removal torque will diminish. In addition, a 3D model was developed to simulate the interfacial shear strength. This was converted to a theoretical removal torque that was compared to the removal torque obtained in vivo. MATERIAL AND METHODS Condensation implants, inducing bone strains of 0.015, were installed into the left tibia of 24 rabbits. Non-condensation implants were installed into the right tibia. All implants had a moderately rough surface. The implants had an implantation time of 7, 28, or 84 days before the removal torque was measured. The interfacial shear strength at different healing time was estimated by the means of finite element method. RESULTS At 7 days of healing, the condensation implant had an increased removal torque compared to the non-bone-condensation implant. At 28 and 84 days of healing, there was no difference in removal torque. The simulated interfacial shear strength ratios of bone condensation implants at different implantation time were in line with the in vivo data. CONCLUSIONS Moderately rough implants that initially induce bone strain during installation have increased stability during the early healing period. In addition, the finite element method may be used to evaluate differences in interlocking capacity.
منابع مشابه
Diagnostic value of CT and MRI of Temporal Bone in Cochlear Implantation Candidates
Background Cochlear implantation is an approved treatment which can be used to treat severe to profound hearing loss. Imaging before cochlear implant surgery is very important in decision making and assessing the temporal bone anatomy for surgery. We aimed to assess the diagnostic value of high resolution CT scan (HRCT), and MRI of temporal bone in candidate pati...
متن کاملDoes locally delivered Zoledronate influence peri-implant bone formation? - Spatio-temporal monitoring of bone remodeling in vivo.
Bisphosphonates are known for their strong inhibitory effect on bone resorption. Their influence on bone formation however is less clear. In this study we investigated the spatio-temporal effect of locally delivered Zoledronate on peri-implant bone formation and resorption in an ovariectomized rat femoral model. A cross-linked hyaluronic acid hydrogel was loaded with the drug and applied bilate...
متن کاملGuided bone regeneration: A literature review
Guided bone regeneration (GBR) is a reconstructive procedure of alveolar ridge using membranes. This procedure is indicated when there is no sufficient bone for implantation, or in the case of optimal implant installation for esthetic or functional needs. GBR can be performed before implant placement, when there is not enough bone for initial stability of implants and less predictable outcomes ...
متن کاملclinical and radiographic methods of marginal bone loss evaluation after immediate implantation in post-extraction sockets.
Introduction: To achieve the best esthetic and functional results of implantation and patient satisfaction, different protocols of implant therapy have been recommended. Immediate implantation can provide the outcome faster than other protocols making it the treatment of choice. The rate of peri-implant bone resorption should be measured clinically and radiographically as bone support is a key ...
متن کاملModeling Static Bruising in Apple Fruits: A Comparative Study, Part I: Analytical Approach
ABSTRACT- Bruising degrades the quality of fresh apple fruits. Reducing bruise damage is of utmost importance in designing and developing processing equipments. The main objective of the present study was to introduce an analytical method to predict the allowable static load applicable to apple fruits. To predict the strain energy absorbed by the fruit, a point load was applied on the solid sph...
متن کامل