Influence of timing in the fructosamine assay.

نویسندگان

  • E K Frandsen
  • R A Bacchus
چکیده

The fructosamine assay, based on the measurement of the reducing activity in serum at alkaline pH, provides an index of protein glycation. The reducing activity is expressed in equivalents of 1-deoxy-1-morpholinofructose (DMF) by direct comparison with the activity either of this synthetic compound or with a secondary protein standard calibrated against DMF. This study reports the influence of assay timing on the apparent serum fructosamine concentration. The kinetics of alkaline reducing activity in serum differed from that in both DMF and a secondary protein standard. When compared with DMF, activity in serum increased but decreased relative to the protein standard as the pre-incubation interval of the assay was shortened. The use of secondary protein standards results in underestimation of serum fructosamine concentrations when the pre-incubation phase of the assay is shorter than that used for the calibration of the secondary standard. Ascorbate exerted an inhibitory effect in fructosamine assays with pre-incubation times exceeding 5 min. The inhibition increased with both the concentration of ascorbate and the duration of the pre-incubation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Relative potency of commercial calibrators for fructosamine, and their effect on measurements of fructosamine in serum.

The protein-based secondary standardsfor serum fructosamine in a commercial test kit (Roche Diagnostics) have recently been modified by the manufacturer. Under certain assay conditions, the new calibrator gave significantly greater serum fructosamine values than those obtained with the originally supplied calibrator. However, for 20-4, samples and absorbance measurements at 10 and 15 mm, hereaf...

متن کامل

Influence of varying timing angle on performance of an SI engine: An experimental and numerical study

Engine performance depends on two main factors of engine speed and ignition time. Ignition timing can affect engine life, fuel economy and engine power. In this paper, to study engine performance of Peugeot 206 TU3A with comparison ratio of 10.5:1 and displacement of 1361CC in MATLAB software, a two-zone burned/unburned model with the fuel burning rate described by aWiebe function was used for ...

متن کامل

Fructosamine assay using albumin extracted from serum.

Albumin extracted from serum by a simple technique using trichloroacetic acid and ethanol has been applied to a fructosamine assay using nitroblue tetrazolium. A fructosamine assay using extracted albumin sample was carried out without interference from low molecular weight substances with reducing activities and other proteins with varying concentrations, half-lives and reducing activities. 1-...

متن کامل

Assay of serum fructosamine that minimizes standardization and matrix problems: use to assess components of biological variation.

Methodological problems with the assay of fructosamine in serum--standardization, matrix effects, and dependence on buffer pH--have been minimized with a method involving colorimetric assay of each specimen and subsequent re-assay after standard addition of 1-deoxy-1-morpholinofructose. Absorbance at optimum wavelength of 540 nm varies linearly with fructosamine concentration to at least 5.5 mm...

متن کامل

Chemistry of the fructosamine assay: D-glucosone is the product of oxidation of Amadori compounds.

The chemistry of the fructosamine assay was studied by using the Amadori compound, N alpha-formyl-N epsilon-fructose-lysine (fFL), an analog of glycated lysine residues in protein. Previously (Clin Chem 1993;39:2460-5), we reported that free lysine was formed from fFL at 70% yield during incubation with alkaline nitroblue tetrazolium (NBT) under the conditions routinely used for the fructosamin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 34 11  شماره 

صفحات  -

تاریخ انتشار 1988