DXA: can it be used as a criterion reference for body fat measurements in children?

نویسندگان

  • Roman J Shypailo
  • Nancy F Butte
  • Kenneth J Ellis
چکیده

OBJECTIVE Dual-energy X-ray absorptiometry (DXA) is often cited as a criterion method for body composition measurements. We have previously shown that a new DXA software version (Hologic Discovery V12.1) will affect whole-body bone mineral results for subjects weighing <40 kg. We wished to reanalyze pediatric whole-body scans in order to assess the impact of the new software on pediatric soft-tissue body composition estimates. METHODS AND PROCEDURES We reanalyzed 1,384 pediatric scans (for ages 1.7-17.2 years) using Hologic software V12.1, previously analyzed using V11.2. Regression analysis and ANCOVA were used to compare body fat (total body fat (TBF), percentage fat (%BF)), and non-bone lean body mass (LBM) for the two versions, adjusting for gender, age and weight. RESULTS Software V12.1 yielded values that were higher for TBF, lower for LBM, and unchanged for DXA-derived weight in subjects weighing <40 kg. Body composition values for younger, smaller subjects were most affected, and girls were more affected than boys. Using the new software, 14% of the girls and 10% of the boys were reclassified from the "normal" %BF range to "at risk of obesity," while 7 and 5%, respectively, were reclassified as obese. DISCUSSION Hologic's newest DXA software has a significant effect on soft-tissue results for children weighing <40 kg. The effect is greater for girls than boys. Comparison of TBF estimates with previous studies that use older DXA instruments and software should be done with caution. DXA has not yet achieved sufficient reliability to be considered a "gold standard" for body composition assessment in pediatric studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of body fat using leg to leg bioimpedance.

AIMS (1) To validate a leg to leg bioimpedance analysis (BIA) device in the measurement of body composition in children by assessment of its agreement with dual energy x ray absorptiometry (DXA) and its repeatability. (2) To establish a reference range of percentage body fat in Hong Kong Chinese children. METHODS Sequential BIA and DXA methods were used to determine body composition in 49 chi...

متن کامل

Use of Fat Mass and Fat Free Mass Standard Deviation Scores Obtained Using Simple Measurement Methods in Healthy Children and Patients: Comparison with the Reference 4-Component Model

BACKGROUND Clinical application of body composition (BC) measurements for individual children has been limited by lack of appropriate reference data. OBJECTIVES (1) To compare fat mass (FM) and fat free mass (FFM) standard deviation scores (SDS) generated using new body composition reference data and obtained using simple measurement methods in healthy children and patients with those obtaine...

متن کامل

Reference standards for body fat measures using GE dual energy x-ray absorptiometry in Caucasian adults

BACKGROUND Dual energy x-ray absorptiometry (DXA) is an established technique for the measurement of body composition. Reference values for these variables, particularly those related to fat mass, are necessary for interpretation and accurate classification of those at risk for obesity-related health complications and in need of lifestyle modifications (diet, physical activity, etc.). Currently...

متن کامل

Validity of Four Commercial Bioelectrical Impedance Scales in Measuring Body Fat among Chinese Children and Adolescents

The aim of the study is to examine the validity in predicting body fat percentage (%BF) of different bioelectrical impedance (BIA) devices among Chinese children and adolescents. A total of 255 Chinese children and adolescents aged 9-19 years old participated in the study. %BF was assessed by BIA scales, namely, Biodynamics-310 (Model A), Tanita TBF-543 (Model B), Tanita BC-545 (Model C), and I...

متن کامل

Prediction of fat-free body mass from bioelectrical impedance and anthropometry among 3-year-old children using DXA

For 3-year-old children suitable methods to estimate body composition are sparse. We aimed to develop predictive equations for estimating fat-free mass (FFM) from bioelectrical impedance (BIA) and anthropometry using dual-energy X-ray absorptiometry (DXA) as reference method using data from 99 healthy 3-year-old Danish children. Predictive equations were derived from two multiple linear regress...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Obesity

دوره 16 2  شماره 

صفحات  -

تاریخ انتشار 2008