Monitoring of physiological parameters during high frequency ventilation (HFV).
نویسندگان
چکیده
Non-biological descriptors such as jet feeding pressure and oscillator stroke volume are often used to describe HFV. This results in confusion and hinders acceptance of HFV. The goal of this paper is to show how physiological parameters which are valid during HFV can be monitored. Airway pressure measured in narrow tubes with high linear flow rates is underestimated. A relevant airway pressure must be measured well below the tracheal tube. Pressure measured higher up should be validated against peripheral pressure measurements. Minute ventilation and expired CO2 concentration can be determined with a ServoVentilator and a CO2 analyzer arranged at its exit port. Minute ventilation and CO2 elimination can thereby be continuously monitored during high frequency jet ventilation or so-called "combined high frequency jet ventilation" to prevent undetected disturbance of ventilation and perfusion. Physiological dead space can be studied for optimization of ventilatory pattern. The principle of gas analysis at the exit port of the ventilator may be used for FRC determinations with sulfur-hexafluoride.
منابع مشابه
The use of high-frequency ventilation during general anaesthesia: an update
Various forms of high-frequency ventilation (HFV) have been described. HFV is broadly defined as artificial ventilation of the lungs with sub-deadspace tidal volumes delivered using supra-physiological frequencies. HFV has been used in anaesthesia and intensive care for special procedures and conditions since the 1960s. Clinical interest in the use and the technical evolution of HFV has develop...
متن کاملAdvanced Monitoring System for Conventional and High Frequency Ventilation
Th ere are many techniques of conventional artifi cial lung ventilation (CV) that are widely used in clinical practice. However, these techniques can cause severe lung damages and also circulatory problems. Searching for new methods of artifi cial lung ventilation (ALV) that can provide the necessary gas exchange in lungs leads to implementation of new unconventional ventilatory techniques, esp...
متن کاملVentilator-induced pulse pressure variation in neonates.
During positive pressure ventilation, arterial pressure variations, like the pulse pressure variation (PPV), are observed in neonates. However, the frequency of the PPV does not always correspond with the respiratory rate. It is hypothesized that PPV is caused by cardiopulmonary interaction, but that this mismatch is related to the low respiratory rate/heart rate ratio. Therefore, the goal of t...
متن کاملFunctional Lung Imaging during HFV in Preterm Rabbits
Although high frequency ventilation (HFV) is an effective mode of ventilation, there is limited information available in regard to lung dynamics during HFV. To improve the knowledge of lung function during HFV we have developed a novel lung imaging and analysis technique. The technique can determine complex lung motion information in vivo with a temporal resolution capable of observing HFV dyna...
متن کاملThe role of high-frequency ventilation in neonates: evidence-based recommendations.
High-frequency ventilation (HFV) uses small tidal volumes and extremely rapid ventilator rates. Despite the wealth of laboratory and clinical research on HFV, there are no established guidelines for prioritizing the use of HFV versus conventional mechanical ventilation (CMV) in neonatal respiratory failure. Examination of the currently available randomized controlled trials and meta-analysis of...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Acta anaesthesiologica Scandinavica. Supplementum
دوره 90 شماره
صفحات -
تاریخ انتشار 1989