WITHDRAWN: Gauze and tape and transparent polyurethane dressings for central venous catheters.
نویسندگان
چکیده
BACKGROUND Central venous catheters (CVCs) facilitate venous access, allowing the intravenous administration of complex drug treatments, blood products and nutritional support, without the trauma associated with repeated venepuncture. However, CVCs are associated with a risk of infection. Some studies have indicated that the type of dressing used with them may affect the risk of infection. Gauze and tape, transparent polyurethane film dressings such as Tegaderm® and Opsite®, and highly vapour-permeable transparent polyurethane film dressings such as Opsite IV3000®, are the most common types of dressing used to secure CVCs. Currently, it is not clear which type of dressing is the most appropriate. OBJECTIVES To compare gauze and tape with transparent polyurethane CVC dressings in terms of catheter-related infection, catheter security, tolerance to dressing material and dressing condition in hospitalised adults and children. SEARCH METHODS For this third update, we searched The Cochrane Wounds Group Specialised Register (10 May 2011); The Cochrane Central Register of Controlled Trials (CENTRAL; The Cochrane Library 2011, Issue 2), Ovid MEDLINE (1950 to April Week 4 2011); Ovid MEDLINE (In-Process & Other Non-Indexed Citations, May 11, 2011); Ovid EMBASE (1980 to 2011 Week 18); and EBSCO CINAHL (1982 to 6 May 2011). SELECTION CRITERIA All randomised controlled trials (RCTs) evaluating the effects of dressing type (e.g. gauze and tape versus transparent polyurethane dressings) on CVC-related infection, catheter security, tolerance to dressing material and dressing condition in hospitalised patients. DATA COLLECTION AND ANALYSIS Two review authors independently assessed trial quality and extracted data. We contacted study authors for missing information. MAIN RESULTS Six studies were included in earlier versions of the review. In this update two of the previously included papers have been excluded and two new trials have been added. Of these six trials, four compared gauze and tape with transparent polyurethane dressings (total participants = 337) and two compared different transparent polyurethane dressings (total participants = 126). Catheter-related bloodstream infection was higher in the transparent polyurethane group when compared with gauze and tape; OR 4.19 (95%CI 1.02 to 17.23) however these small trials were at risk of bias so this evidence is graded low quality. There was no evidence of a difference between highly permeable polyurethane dressings and other polyurethane dressings in the prevention of catheter-related bloodstream infection (low quality evidence). No other significant differences were found. AUTHORS' CONCLUSIONS We found a four-fold increase in the rate of catheter related blood stream infection when a polyurethane dressing was used to secure the central venous catheter however this research was at risk of bias and the confidence intervals were wide indicating high uncertainty around this estimate; so the true effect could be as small as 2% or as high as 17-fold. More, better quality research is needed regarding the relative effects of gauze and tape versus polyurethane dressings for central venous catheter sites.
منابع مشابه
Chlorhexidine and gauze and tape dressings for central venous catheters: a randomized clinical trial 1
OBJECTIVE To assess the effectiveness of the chlorhexidine antimicrobial dressing in comparison to the gauze and tape dressing in the use of central venous catheters. METHOD A randomized clinical trial was conducted in the intensive care and adult semi intensive care units of a university hospital in the south of Brazil. The subjects were patients using short-term central venous catheters, ra...
متن کاملA prospective, randomized trial of gauze and two polyurethane dressings for site care of pulmonary artery catheters: implications for catheter management.
OBJECTIVES To compare the safety of a conventional polyurethane transparent dressing and a novel highly permeable polyurethane dressing, as compared with standard gauze and tape, as site dressings for pulmonary artery catheters; and to rigorously determine the sources of bloodstream infections deriving from these catheters. DESIGN Prospective, randomized, clinical trial. SETTING General adu...
متن کاملRisk factors for recurrent central line-associated bloodstream infections in a pediatric intensive care unit
Background/aim: It is recommended that a central venous catheter (CVC) be removed if central line-associated bloodstream infection (CLABSI) has been diagnosed. The objective of this retrospective study was to evaluate the risk factors for recurrent CLABSI in reinserted catheters in a pediatric intensive care unit. Materials and methods: Patients with recurrent and nonrecurrent CLABSI were compa...
متن کاملThe use of polyurethane transparent film in indwelling central venous catheter.
Dressing is an intervention aimed to prevent infection in central venous catheter. This study aimed to analyze the frequency of catheter-related infection and skin toxicity in the use of transparent film in Hickman's catheter in patients who underwent allogeneic hematopoietic stem cell transplantation. A case series with 10 cases was carried out. Due to the presence of exudate on the average fo...
متن کاملDevices and dressings to secure peripheral venous catheters to prevent complications.
BACKGROUND A peripheral venous catheter (PVC) is typically used for short-term delivery of intravascular fluids and medications. It is an essential element of modern medicine and the most frequent invasive procedure performed in hospitals. However, PVCs often fail before intravenous treatment is completed: this can occur because the device is not adequately attached to the skin, allowing the PV...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Cochrane database of systematic reviews
دوره 4 شماره
صفحات -
تاریخ انتشار 2003