Detecting Geyser Activity with Infrasound

نویسندگان

  • Jeffrey B. Johnson
  • J. F. Anderson
  • R. E. Anthony
  • M. Sciotto
  • J. B. Johnson
چکیده

We monitored geyser activity in the Lower Geyser Basin (LGB) of Yellowstone National Park with dual four-element microphone arrays separated by ~600 m. The arrays were independently used to identify incident coherent plane wave energy, then conjoint cross beam back-azimuths from the two arrays were used to precisely locate signal sources. During a week in August 2011 we located repeating infrasound events, peaked in energy between 1 and 10 Hz, originating from at least five independent geothermal features, including the episodically erupting Great Fountain, Fountain and Kaleidoscope Geysers, as well as periodic infrasound from nearby Botryoidal and persistent sound from Firehole Spring. Although activity from nearby cone-type geysers was not detected in the infrasound band up through 50 Hz, the major fountain-type geysers (i.e., with columns greater than 10 m) could be detected at several kilometers, and two minor geysers (i.e., a few meters in eruption height) could be tracked at distances up to a few hundred meters. Detection of geyser activity was especially comprehensive at night when ambient noise was low. We conclude that infrasound monitoring of fountain-type geysers permits convenient tracking of geyser activity, episodicity, signal duration, energy content, and spectral content. These parameters enable objective statistical quantification of geyser behavior and changes over time that may be due to external forcing. Infrasonic study of geyser activity in an individual basin has great monitoring utility and can be reasonably accomplished with two or more distributed sensor arrays.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The inaudible sound of thunderstorms

By measuring infrasound, a wide variety of atmospheric sources can be identified. In this study, infrasound associated with thunderstorm lightning discharges is investigated. For this purpose, infrasound observations are compared with discharge detections based on a electromagnetical (EM) detection system. Both systems are operated by the Royal Netherlands Meteorlogical Institute. The initial r...

متن کامل

Changes in geyser eruption behavior and remotely triggered seismicity in Yellowstone National Park produced by the 2002 M 7 . 9 Denali fault earthquake , Alaska

Following the 2002 M 7.9 Denali fault earthquake, clear changes in geyser activity and a series of local earthquake swarms were observed in the Yellowstone National Park area, despite the large distance of 3100 km from the epicenter. Several geysers altered their eruption frequency within hours after the arrival of large-amplitude surface waves from the Denali fault earthquake. In addition, ear...

متن کامل

A Dynamical Model of a Geyser Induced by Boiling: an Application of the Dynamical Model of a Geyser Induced by Inflow of Gas

We have proposed a static model, a dynamical model and a modified dynamical model of a geyser induced by inflow of gas based on observation and model experiments of it and have also proposed a combined model combining above two models. And numerical simulations of the modified dynamical model or the combined model reappear spouting dynamics of a geyser induced by inflow of gas and it becomes po...

متن کامل

Mechanics of Old Faithful Geyser, Calistoga, California

[1] In order to probe the subsurface dynamics associated with geyser eruptions, we measured ground deformation at Old Faithful Geyser of Calistoga, CA. We present a physical model in which recharge during the period preceding an eruption is driven by pressure differences relative to the aquifer supplying the geyser. The model predicts that pressure and ground deformation are characterized by an...

متن کامل

Inhibitory Effects of Low Decibel Infrasound on the Cardiac Fibroblasts and the Involved Mechanism

INTRODUCTION Infrasound is a mechanical vibration wave with frequency between 0.0001 and 20 Hz. It has been established that infrasound of 120 dB or stronger is dangerous to humans. However, the biological effects of low decibel infrasound are largely unknown. The purpose of this study was to investigate the effects of low decibel infrasound on the cardiac fibroblasts. MATERIALS AND METHODS T...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015